Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPECTRO COATING CORP.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SPECTRO COATING CORP. in 101 SCOTT DR, LEOMINSTER, MA 01453 (NAICS 313320). OSHA activity number 342747540.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spectro Coating Corp. — free Get an email when a new federal OSHA severe-injury report for Spectro Coating Corp. is published. One employer, no account, unsubscribe in one click.
Site address
101 SCOTT DR
City
LEOMINSTER
State
MA
ZIP
01453
Mailing
101 SCOTT DR, LEOMINSTER, MA 01453
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313320
Employees
70
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 70 exposed
Issued
Apr 27, 2018
Abate by
Dec 28, 2018
Penalty
Initial $9,054 · Current $5,013 Reduced

Hazardous substances E200M102

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to the hazards of dust explosions, deflagrations, and other fire hazards:    Range 1 Flock Room:  On or about 11/2/17, the flock modules, which apply flock onto cloth, were not equipped and used in a safe manner.  Employees were exposed to the hazards of dust explosions, deflagrations, and other fire hazards due to potential sources of ignition including, but not limited to, electrostatic grids in the flock modules, static electricity discharges, sparks originating from tramp metal getting entrained into the system, and mechanical failures causing overheating of components.  On 11/2/17, an employee was burned when the combustible dust in the Range 1 flock machine ignited.
Recent events (2)
  • — I (S) $5012.75
  • — Z (S) $9054

1910.22 A01

Serious Gravity 10 1 instance 70 exposed
Issued
Apr 27, 2018
Abate by
Dec 28, 2018
Penalty
Initial $9,054 · Current $0 Reduced

Hazardous substances E200M102

29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:    Range 1 Flock Room:  On or about 11/2/17, an accumulation of combustible nylon dust over 1/32 of an inch thick was located on an area which comprised over 5% of the area of the room, including, but not limited to the top and other sections of the flock modules, electrical boxes, and other surfaces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.132 A

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 27, 2018
Abate by
Jul 2, 2018
Penalty
Initial $9,054 · Current $5,013 Reduced

Hazardous substances E200M102

29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    Range 1 Flock Room:  On or about 11/2/17, employees exposed to fire/deflagration/explosion hazards were not wearing fire-resistant clothing such as, but not limited to, long pants and long sleeves to protect them from burns.  An employee was burned on the parts of his body which were exposed.
Recent events (2)
  • — I (S) $5012.75
  • — Z (S) $9054

1910.134 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 27, 2018
Abate by
Jun 1, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  Range 1 Flock Room: On or about 11/2/17, employees wearing filtering-facepiece respirators, as required by the employer, had not been provided medical evaluations to determine their ability to use a respirator.
Recent events (2)
  • — I (S) $5174
  • — Z (S) $5174

1910.145 C03

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 27, 2018
Abate by
Jun 1, 2018
Penalty
Initial $9,054 · Current $5,013 Reduced

Hazardous substances E200M102

29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):    Range 1 Flock Room:  On or about 11/2/17, caution signs regarding combustible dust fire/explosion hazards were not installed on the flock machine or in the flock room to warn employees of the combustible/explosive properties of the dust.
Recent events (2)
  • — I (S) $5012.75
  • — Z (S) $9054

1910.1200 H01

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 27, 2018
Abate by
Jun 1, 2018
Penalty
Initial $0 · Current $0

Hazardous substances E200M102

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Range 1 Flock Room: On or about 11/2/17, employees were not provided effective information and training on the hazards of combustible dust.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 27, 2018
Abate by
May 3, 2018
Penalty
Initial $9,054 · Current $5,013 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      101 Scott Dr., Leominster, MA      On February 6, 2018 and at times prior, employees who thoroughly cleaned Flock Room machines during a color change did not utilize the energy control procedure and did not lock out the electrical source of energy.  Employees lifted hinged guards to clean brushes, belts, and pulleys.
Recent events (2)
  • — I (S) $5012.75
  • — Z (S) $9054

1910.147 C06 I

Serious Gravity 10 1 instance 20 exposed
Issued
Apr 27, 2018
Abate by
Jul 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    101 Scott Dr., Leominster, MA    As of November 28, 2017, the employer had not performed a periodic inspection that ensured each procedure was inspected for inaccuracies during an actual energy control task.  The employer did not include a review, between the inspector and every authorized employee, of each employee's responsibilities under the energy control procedure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 II D

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 27, 2018
Abate by
May 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:     101 Scott Dr., Leominster, MA  On February 6, 2018 and at times prior, employees who cleaned Flock Room machines during non-color changes were protected by the lead person's lockout device, but did not always apply their own lock to the energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Spectro Coating Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342747540.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.