Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CA ARMY NATIONAL GUARD - CAMP ROBERTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CA ARMY NATIONAL GUARD - CAMP ROBERTS in HWY 101, DPW-BLDG 3024 CAMP ROBERTS, SAN MIGUEL, CA 93451 (NAICS 928110). OSHA activity number 342747763.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CA Army National Guard - Camp Roberts — free Get an email when a new federal OSHA severe-injury report for CA Army National Guard - Camp Roberts is published. One employer, no account, unsubscribe in one click.
Site address
HWY 101, DPW-BLDG 3024 CAMP ROBERTS
City
SAN MIGUEL
State
CA
ZIP
93451
Mailing
BUILDING 3022 CAMP ROBERTS, SAN MIGUEL, CA 93451
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
16
Ownership type
D

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 16 exposed
Issued
Mar 13, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Building 3024, Shop: The following electric drills were not guarded and employees were exposed to lacerations;       a)  Skill  Drill - Model #3220  S/ 504     b)  Delta Drill  S/N 627298A86     c)  General  Drill  S/N AB 1106  Model 340     d)  General Drill  S/N AH 3142/ G62899     e)  Rockwell  S/N 1810737-15     f)   Delta Model  15  S/N 627261
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 16 exposed
Issued
Mar 13, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  Building 3024- Shop: The Craftsman Drill (s/n 11324610) electric drill was not securely attached to the floor.  It was used for drilling metal and wood and employees were exposed to struck-by hazards.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 2 instances 16 exposed
Issued
Mar 13, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   Buildings 3023-3024:  Electrical panels had openings that could allow unintentional contact with live inner conductors exposing employees to electrical hazards in the following areas:      a)  Junction box controlling the table saw     b)  Dee Blast Corp glove box           c)  General Electric panel
Recent events (1)
  • — Z (S) $0

1910.22 D01

Other-than-serious 1 instance 11 exposed
Issued
Mar 13, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  Warehouse Building 3024:  The mezzanine was not marked with the load rating and was used for storage of employee lockers, pallets, industrial and miscellaneous supplies.
Recent events (1)
  • — Z (O) $0

1910.212 A03 II

Other-than-serious 1 instance 3 exposed
Issued
Mar 13, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded. The guarding device shall be in conformity with any appropriate standards therefore, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle:   Office: The paper cutter used by office workers did not have a guard as required by manufacturer and the operators were exposed to lacerations.
Recent events (1)
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 16 exposed
Issued
Mar 13, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  Building 3024, break room: An electrical outlet cover which energized the refrigerator was damaged and could allow unintentional contact with live inner conductors.
Recent events (1)
  • — Z (O) $0