SAN MIGUEL, CA —
OSHA Inspection: CA ARMY NATIONAL GUARD - CAMP ROBERTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CA ARMY NATIONAL GUARD - CAMP ROBERTS in BLDG 3024 CAMP ROBERTS, SAN MIGUEL, CA 93451 (NAICS 561210). OSHA activity number 348658907.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CA ARMY NATIONAL GUARD - CAMP ROBERTS
- Site address
- BLDG 3024 CAMP ROBERTS
- City
- SAN MIGUEL
- State
- CA
- ZIP
- 93451
- Mailing
- CAMP ROBERTS, HWY 101 BLDG. 3024, SAN MIGUEL, CA 93451
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- Employees
- 36
- Ownership type
- D
Citations
8 citations on file for this inspection.
1910.28 B01 I A
- Issued
- Feb 11, 2026
- Abate by
- Mar 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a standard guardrail system. Water Treatment Plant: On or about December 17, 2025, and at times prior to, the employer did not ensure that their trickling filter one structure had proper guarding. This condition potentially exposed employees to fall hazards.
Recent events (1)
- — Z (S) $0
1910.133 A01
- Issued
- Feb 11, 2026
- Abate by
- Mar 10, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: Water Treatment Plant: On or about December 17, 2025, and at time prior to, the employer did not ensure that employees pouring Muriatic Acid from its original container into a secondary container were wearing goggles. This condition potentially exposed employees to chemical hazards.
Recent events (1)
- — Z (S) $0
1910.334 A04
- Issued
- Feb 11, 2026
- Abate by
- Mar 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(4): Portable electric equipment and flexible cords that was used in highly conductive work locations (such as those inundated with water or other conductive locations) or in job locations where employees were likely to contact water or conductive liquids were not approved for those locations: Water Treatment Plant: On or about December 17, 2025, and at times prior to, the employer did not ensure that a flexible cord used for power was not exposed to water or submersion in their sump pit. This condition potentially exposed employees to electrical shock hazards.
Recent events (1)
- — Z (S) $0
1904.40 A
- Issued
- Feb 11, 2026
- Abate by
- Mar 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. Department of Public Works: On December 17, 2025, the employer did not ensure that OSHA 300 log for the past 3 years were readily available and provided to the authorized government representative within 4 business hours.
Recent events (1)
- — Z (O) $0
1910.23 B10
- Issued
- Feb 11, 2026
- Abate by
- Mar 9, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(b)(10): The employer did not ensure that any ladder with structural or other defects as immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with § 1910.145 and removed from service until repaired in accordance with § 1910.22(d), or replaced. Building 3024: On December 17, 2025, and at times prior to, the employer did not ensure that their A-frame ladder were appropriately labeled with markings or decals to identify the load limits when working on their attic renovation. This condition potentially exposed employees to fall hazards.
Recent events (1)
- — Z (O) $0
1910.37 A04
- Issued
- Feb 11, 2026
- Abate by
- Mar 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: Warehouse, Building 3018: On or about December 17, 2025, an at times prior to, the employer did not ensure that the exit lighting on the south door was in working order. This condition potentially exposed employees to egress hazards.
Recent events (1)
- — Z (O) $0
1910.37 B02
- Issued
- Feb 11, 2026
- Abate by
- Mar 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit": Warehouse, Building 3018: On or about December 17, 2025, and at times prior to, the employer did not ensure that their exits at the rear of the warehouse were clearly labeled with a sign that reads "Exit". This condition potentially exposed employees to egress hazards.
Recent events (1)
- — Z (O) $0
1910.157 E03
- Issued
- Feb 11, 2026
- Abate by
- Mar 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Throughout Department of Public Works: On or about December 17, 2025 and at times prior there to, the employer did not ensure that fire extinguishers throughout their facility were subjected to an annual maintenance check. This condition potentially exposed employees to fire hazards.
Recent events (1)
- — Z (O) $0
More inspections at CA Army National Guard - Camp Roberts
View CA Army National Guard - Camp Roberts's full OSHA safety record →
More inspections in this industry (NAICS 561210)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348658907.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.