PLYMOUTH, IL —
OSHA Inspection: GLENVIEW PORK, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GLENVIEW PORK, LLC in 2495 EAST COUNTY ROAD 650, PLYMOUTH, IL 62367 (NAICS 112210). OSHA activity number 342751047.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLENVIEW PORK, LLC
- Site address
- 2495 EAST COUNTY ROAD 650
- City
- PLYMOUTH
- State
- IL
- ZIP
- 62367
- Mailing
- 2495 EAST COUNTY ROAD 650, PLYMOUTH, IL 62367
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 112210
- Employees
- 12
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.36 D01
- Issued
- Feb 26, 2018
- Penalty
- Initial $2,217 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors: On or about November 3, 2017, employees in the Breeding Barn (Barn 5) were exposed to smoke inhalation and burn hazards when the exit doors could not be opened: a) North Exit Door - secured by a wire attached between the handle and door jamb; and b) South Exit Door - missing the handle and deadbolt knob needed to operate the closure mechanisms.
Recent events (2)
- — I (O) $1200
- — Z (S) $2217
1910.37 B02
- Issued
- Feb 26, 2018
- Abate by
- Mar 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit.": On or about November 3, 2017, employees were exposed to smoke inhalation hazards and each exit was not clearly visible and marked by a sign reading "Exit," including: a) Hallway between the Office and Breeding Barn (Barn 5); and b) Hallway leading into Barn F1.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 C01
- Issued
- Feb 26, 2018
- Abate by
- Mar 27, 2018
- Penalty
- Initial $2,956 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): The employer failed to have a written respiratory protection program in place for employees required to utilize respirators in the performance of their job tasks. On or about November 2, 2017, employees wore tight-fitting half-mask respirators when power washing the barns with Barnstorm and the employer did not develop and implement a written respiratory protection program.
Recent events (2)
- — I (S) $0
- — Z (S) $2956
1910.134 E01
- Issued
- Feb 26, 2018
- Abate by
- Mar 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about November 2, 2017, employees wore tight-fitting half-mask respirators and the employer did not provide a medical evaluation prior to use of the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Feb 26, 2018
- Abate by
- Mar 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about November 2, 2017, the employer did not provide an annual fit test for the employees who wore tight-fitting half-mask respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Feb 26, 2018
- Abate by
- Apr 6, 2018
- Penalty
- Initial $2,956 · Current $1,625 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about November 3, 2017, the employer did not provide a suitable face and body wash for quick drenching in the barns and employees were exposed to the following chemicals when making dilutions, cleaning and sanitizing (crates, mats, dividers, feeders, slats, louvers, fan blades, housing units, walls, floors, and the ceilings) with the following: a) Bleach (stock 5.25-percent with a pH at 12.75 diluted 1:1 to pH at 12.68); and b) Barnstorm (pH of 1 to 2).
Recent events (2)
- — I (S) $1625
- — Z (S) $2956
1910.219 C04 I
- Issued
- Feb 26, 2018
- Penalty
- Initial $2,956 · Current $1,625 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Shaft ends projecting more than one-half the diameter of the shaft were not guarded by nonrotating caps or safety sleeves. On or about November 3, 2017, employees walking beneath the Northeast and Northwest In-Feed motors and terminating auger ends at the North side of the Breeding Barn (Barn 5) were exposed to contact with unprotected rotating shafts and the shafts were not protected by caps or safety sleeves.
Recent events (2)
- — I (S) $1625
- — Z (S) $2956
1910.305 B01 III
- Issued
- Feb 26, 2018
- Penalty
- Initial $2,956 · Current $1,625 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(iii): Cable was not secured to the cabinet, cutout box, or meter socket enclosure: On or about November 3, 2017, employees at the Breeding Barn (Barn 5) were exposed to electrical shock and burn hazards and the flexible cords were not secured to the electrical boxes at the feed auger lines, including: a) Line B (South), Chore-Time Controller (230/220V); b) Line B (South), electric motor (115V); c) Line H (South), Chore-Time Controller (230/220V); d) Northwest side In-Feed electric motor, GSI Group FX4512 electrical box assembly (240V); and e) Northeast side In-Feed electric motor (115V).
Recent events (2)
- — I (S) $1625
- — Z (S) $2956
1910.305 B02 I
- Issued
- Feb 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose; and each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about November 3, 2017, employees at the South side of Breeding Barn (Barn 5) were exposed to electrical shock and burn hazards and the junction box covers were missing from the following electrically fed equipment at the feed auger lines, including: a) Line A electric motor (115V); b) Line D electric motor (115V); c) Line F Chore-Time Controller (230/220V); and d) Line G electric motor (115V).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 E02
- Issued
- Feb 26, 2018
- Abate by
- Mar 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures: On or about November 3, 2017, employees in the Dead Hallway used a light switch that becomes wet while power washing the walls and floor and the switch was not enclosed in a weatherproof enclosure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Feb 26, 2018
- Penalty
- Initial $2,956 · Current $1,625 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about November 3, 2017, employees were exposed to detergents and disinfectants and the employer did not develop, implement, and maintain a written hazard communication program with at least a description of how the criteria for the following requirements would be met by the company: a) use of labels and other forms of warning, b) access to safety data sheets, c) provision of hazardous chemical information and training to employees, d) maintenance of an updated list of hazardous chemicals present at the job site, e) methods the employer will use to inform employees of the hazards of non-routine tasks and hazards associated with chemicals contained in unlabeled pipes in their work areas. f) methods the employer will use to inform other employers on-site on their precautionary measures to protect employees during normal operating conditions and in foreseeable emergencies, the labeling system used in the workplace and to provide other employers on-site access to safety data sheets.
Recent events (2)
- — I (O) $1625
- — Z (S) $2956
1910.1200 H01
- Issued
- Feb 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about November 3, 2017, employees prepared and used detergent and disinfectant solutions and the employer did not provide employees information and training on the hazardous chemicals in their work area and the pictograms.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Glenview Pork, LLC