Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GLENVIEW PORK, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GLENVIEW PORK, LLC in 2495 EAST COUNTY ROAD 650, PLYMOUTH, IL 62367 (NAICS 112210). OSHA activity number 343993648.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Glenview Pork, LLC — free Get an email when a new federal OSHA severe-injury report for Glenview Pork, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GLENVIEW PORK, LLC
Site address
2495 EAST COUNTY ROAD 650
City
PLYMOUTH
State
IL
ZIP
62367
Mailing
2495 EAST COUNTY ROAD 650, PLYMOUTH, IL 62367
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112210
Employees
11
Ownership type
A

10 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.22(d)(1): Walking-working surfaces were not inspected, regularly, and maintained in a safe condition.    On or about May 8, 2019 employees were exposed to slip, trip, and fall hazards due to walking-working surfaces not being inspected regularly allowing conditions to exist, such as but not limited to: open floor holes.
Recent events (3)
  • — R (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1910.22 D02

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(2): Hazardous conditions were not immediately repaired or properly guarded before an employee used the walking-working surface.   On or about May 8, 2019 employees were exposed to slip, trip, and fall hazards due to the walking-working surface in Fairing Room 3 not being repaired or guarded from use to prevent employees from walking into open floor holes.
Recent events (3)
  • — R (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $4,546 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about May 8, 2019 employees were exposed to contact with the unguarded portion of the pulleys on the Fairing Room #1 feed auger because pulley nip points were not enclosed.
Recent events (3)
  • — R (S) $0
  • — C (S) $4546
  • — Z (S) $4546

1910.219 E03 I

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1010.219(m) and (o):    On or about May 8, 2019 employees were exposed to contact with belts on the Fairing Room #1 feed auger because the drive belts were not guarded.
Recent events (3)
  • — R (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed.    On or about May 8, 2019 employees were exposed to nip and sheer points when using the boar block because the rear portion of the machine is missing the guard exposing the drive chains and sprockets.
Recent events (3)
  • — R (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1910.303 G01 II

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.     On or about May 8, 2019 employees were exposed to electrical hazards when the electrical panel boxes in the G1 Storage Closet were blocked by material.  The employer did not ensure that the working space about electrical equipment was free of material and not used for storage.
Recent events (3)
  • — R (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1910.305 B01 II

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii):  Unused openings in boxes, cabinets, or fittings were not effectively closed:    On or about May 8, 2019 employees accessing the panel box west of the Gestation Room 1 hallway were exposed to the hazard of electrical shock when using the circuit breaker panel because an unused breaker opening was not effectively closed to prevent contact with live parts.
Recent events (3)
  • — R (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1910.305 C04

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface:    On or about May 8, 2019 the employer did not ensure that a snap switch that operated the Gestation Room 1 feed auger had a faceplate installed so as to prevent accidental contact with electrical current exposing employees to electrical hazards.
Recent events (3)
  • — R (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1910.305 G02 III

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:     On or about May 8, 2019 employees were exposed to the hazard of electrical shock when working in and around the hallway of Gestation Room 1 because the flexible power cord providing power to the hallway lighting was not connected to the light fixture with devices and fittings that would have prevented tension from being transmitted to the flexible cords.
Recent events (3)
  • — R (S) $0
  • — C (S) $3031
  • — Z (S) $3031

1910.305 B02 I

Repeat Gravity 5 3 instances 9 exposed
Issued
Sep 16, 2019
Abate by
Oct 1, 2019
Penalty
Initial $6,062 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    On or about May 8, 2019 employees working in Room 7, Farrowing Room 1, and Gestation Room 1 were exposed to accidental contact with live electrical conductors because junction boxes and pull boxes were not guarded with an approved cover.    Glenview Pork, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(2)(i), which was contained in OSHA inspection number 1275104, citation number 1, item number 5b and was affirmed as a final order on March 20, 2018, with respect to a workplace located at 2495 East County Road 650, Plymouth, IL 62367.
Recent events (3)
  • — R (R) $0
  • — C (R) $6062
  • — Z (R) $6062

View Glenview Pork, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343993648.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.