OSHA Inspection: PARIS CLEANERS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PARIS CLEANERS, INC. in 650 ENTERPRISE PKWY, RAVENNA, OH 44266 (NAICS 333312). OSHA activity number 342756566.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paris Cleaners, INC. — free Get an email when a new federal OSHA severe-injury report for Paris Cleaners, INC. is published. One employer, no account, unsubscribe in one click.
Site address
650 ENTERPRISE PKWY
City
RAVENNA
State
OH
ZIP
44266
Mailing
67 HOOVER PARKWAY, DUBOIS, PA 15801
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333312
Employees
800
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 15, 2017
Penalty
Initial $7,696 · Current $5,387 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     On or about November 2, 2017, the employer did not ensure procedures were utilized for the safe application, usage, and removal of potentially hazardous energy controls during the service and repair of a conveyor belt at the Press #2 coinc conveyer.
Recent events (2)
  • — I (S) $5387
  • — Z (S) $7696

1910.147 D

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:   On or about November 2, 2017, the employer did not ensure employees implemented energy control procedures during the service and adjustment of the conveyer belt of the Press #2 coinc conveyer by, turning off and/or shutting down [per the 1910.147(d)(1) requirements], isolating all energy sources [(d)(3)], affixing a lockout device to each energy isolating device [(d)(4)], and verify the equipment energy was isolated and de-energized prior to starting work [(d)(6)].
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Paris Cleaners, INC.'s full OSHA safety record →