Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DENTALEZ ALABAMA, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DENTALEZ ALABAMA, INC. in 2500 US HWY-31 S, BAY MINETTE, AL 36507 (NAICS 339114). OSHA activity number 342759891.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dentalez Alabama, INC. — free Get an email when a new federal OSHA severe-injury report for Dentalez Alabama, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2500 US HWY-31 S
City
BAY MINETTE
State
AL
ZIP
36507
Mailing
2500 US HWY-31 S, BAY MINETTE, AL 36507
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339114
Employees
92
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2018
Penalty
Initial $6,911 · Current $6,400 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm including injuries from crushing or tip over of racks and stored items to employees in that employees were exposed to crush by or falling object hazards from storage racks not being secured to the concrete floor.       a)        Paint Area:  On or about November 8, 2017 and at times prior to, the employer exposed employees to crushing hazards and injuries from storage racks not being secured or bolted to concrete floor.
Recent events (3)
  • — J (S) $6400
  • — C (S) $6911
  • — Z (S) $6911

5(a)(1)

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Feb 5, 2018
Abate by
Feb 15, 2018
Penalty
Initial $8,638 · Current $0 Reduced

Hazardous substances E200

Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm including severe burns, to employees in that employees were exposed to a dust explosion, deflagration, or other fire hazards from combustible powder paint dust created from electrostatic painting operation.       a)     Electrostatic Powder Paint Spray Finishing Operation Area:  November 8, 2017 and at times prior to, employees were exposed to fire and explosion hazards from combustible powder paint dust air separation system and powder paint recovery box being located inside of the building.      b)    Electrostatic Powder Paint Spray Finishing Operation Area:  November 8, 2017 and at times prior to, employees were exposed to fire and explosion hazards from combustible powder paint dust process that was not protected from deflagration hazards.
Recent events (3)
  • — J (S) $0
  • — C (S) $8638
  • — Z (S) $8638

1910.94 C07 III B

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 5, 2018
Abate by
Feb 13, 2018
Penalty
Initial $5,182 · Current $4,500 Reduced

Hazardous substances 00400430108013852460

29 CFR 1910.94(c)(7)(iii)(b): A pressure gage marked to show the pressure drop across the filters of the spray booth to indicate that the filters require cleaning or replacement was not installed:      a)    Wet Spray Paint Booth: On or about November 8, 2017 and at times prior to, the employer exposed employees to fire and inhalation hazards by not ensuring a gauge was installed that will show pressure drop across filters.
Recent events (3)
  • — J (S) $4500
  • — C (S) $5182
  • — Z (S) $5182

1910.107 B10

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2018
Penalty
Initial $6,911 · Current $6,911

Hazardous substances 04301080138524602470

29 CFR 1910.107(b)(10): Transparent panels used for illumination of spray booth(s) did not effectively isolate the spraying area from the area in which the lighting unit(s) were located:     A)    Spray Paint Booth: On or about November 8, 2017 and at times prior to, the employer exposed employees to fire hazards by permitting employee to performed painting and clear coating operations without effectively isolating the spraying area from the lighting unit.
Recent events (3)
  • — J (S) $6911
  • — C (S) $6911
  • — Z (S) $6911

1910.107 C06

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2018
Abate by
Feb 13, 2018
Penalty
Initial $6,911 · Current $0 Reduced

Hazardous substances 00400430108024602470

29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for     Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:     a)    Spray Paint Booth: On or about November 8, 2017 and at times prior to, the employer exposed employees to fire hazards by not ensuring electrical equipment was of a Class I, Div. 1 in the spray booth.
Recent events (3)
  • — J (S) $0
  • — C (S) $6911
  • — Z (S) $6911

1910.1200 F06 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 5, 2018
Penalty
Initial $5,182 · Current $4,500 Reduced
29 CFR 1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:      a)     Paint area:  On or about November 21, 2017 and at times prior to, the employer exposed employees to chemical hazards from an unlabeled container without identification of the hazard of the chemical  and identification of the contents of a hand sprayer that contained a corrosive product called LPS Precision Clean.
Recent events (3)
  • — J (S) $4500
  • — C (S) $5182
  • — Z (S) $5182

1910.1200 H01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Feb 5, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 10602210E200

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a)     Paint area:  On or about November 8, 2017 and at times prior to, the employer exposed employees to chemical hazards of corrosive solvents and combustible dusts and did not provide all employees with initial training on the company's Hazard Communication Program.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 D03

Deleted Other-than-serious 1 instance 1 exposed
Issued
Feb 5, 2018
Abate by
Feb 15, 2018
Penalty
Initial $0 · Current $0

Hazardous substances E200

29 CFR 1910.107(d)(3): The spray booth did not have an independent exhaust duct system discharging to the exterior of the building.  a)    Powder Coating Paint Booth: On or about November 8, 2017 and at times prior to, the employer exposed employees to fire and explosion hazards by not providing an independent exhaust duct system to discharge to the exterior of the building.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.107 D09

Deleted Other-than-serious 1 instance 1 exposed
Issued
Feb 5, 2018
Abate by
Feb 15, 2018
Penalty
Initial $0 · Current $0

Hazardous substances E200

29 CFR 1910.107(d)(9): Air exhaust from spray operations was directed so that it will contaminate makeup air being introduced into the spraying area and other ventilating intakes, nor directed so as to create a nuisance. Air exhausted from spray operations was recirculated:   a)    Powder Coating Paint Booth: On or about November 8, 2017 and at times prior to, the employer exposed employees to fire and explosion hazards by allowing exhaust air from the Nordson electrostatic powder paint booth to be recirculated inside the building.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

View Dentalez Alabama, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342759891.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.