Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHEAST FOREST PRODUCTS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOUTHEAST FOREST PRODUCTS CORPORATION in 4596 WASHINGTON FERRY RD., MONTGOMERY, AL 36108 (NAICS 321920). OSHA activity number 342773819.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southeast Forest Products Corporation — free Get an email when a new federal OSHA severe-injury report for Southeast Forest Products Corporation is published. One employer, no account, unsubscribe in one click.
Site address
4596 WASHINGTON FERRY RD.
City
MONTGOMERY
State
AL
ZIP
36108
Mailing
P.O. BOX 1882, MONTGOMERY, AL 36102
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
50
Ownership type
A

14 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $7,114 · Current $7,114
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a)  Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were required to work on equipment to include but not limited to the Baker 5 Head Saw which had multiple energy sources such as electric and air; the machine specific procedures were not developed and documented with all of the required elements and the procedures that were in place were not utilized to ensure that those energy sources were controlled while the employees were performing maintenance or servicing on the machine.
Recent events (3)
  • — A (S) $7114
  • — I (S) $5000
  • — Z (S) $7114

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   a)  Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to potential hazardous energy sources in that the written procedures including but not limited to the procedures for the Baker 5 Head Saw did not have clear and specific steps for isolating, securing, and verifying that the hazardous energy had been controlled.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:   a)  Pallet Mill Machinery; On or about November 14, 2017 and at times prior thereto the employer exposed employees to potential hazardous energies in that the employer had not provided authorized employees locks for isolating and securing machine energy sources including but not limited to the Baker 5 Head Saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:    a) Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were required to work on the Baker 5 Head Saw to replace blades without shutting it down and locking it out in accordance with the company's Lockout program established procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):   a)  Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were required to work on the Baker 5 Head Saw to replace blades without isolating the machine from the energy source - employees were using a stop button versus the machines power disconnect (an energy isolating device) to isolate the machine from the energy source.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $5,691 · Current $5,691
29 CFR 1910.178(q)(7): Industrial trucks were being placed in services after the examination showed condition(s) adversely affecting the safety of the vehicle:   a)  Pallet Mill Area; On or about November 14, 2017 and at times prior thereto the employer exposed employees to struck-by hazards in that employees were allowed to operate a forklift without a working horn.
Recent events (3)
  • — A (S) $5691
  • — I (S) $4000
  • — Z (S) $5691

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $7,114 · Current $7,114
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:   a)  Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to amputation hazards in that employees were allowed to walk and work in close proximity of an unguarded rotating shaft on the red Morgan Saw.
Recent events (3)
  • — A (S) $7114
  • — I (S) $3000
  • — Z (S) $7114

1910.303 B01 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 25, 2018
Penalty
Initial $4,268 · Current $4,268
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as exposed wiring:   a) Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to electrical hazards in that employees were required to walk and work around an electric motor that had no cover on the wire connection box exposing the motors electrical conductors to damage.
Recent events (3)
  • — A (S) $4268
  • — I (S) $3000
  • — Z (S) $4268

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:   a)  Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to electrical hazards in that employees were allowed to walk and work around exposed live conductors hanging from the ceiling from conduit exposing live 480 volt AC 3 phase.
Recent events (3)
  • — A (S) $9959
  • — I (S) $3000
  • — Z (S) $9959

1910.304 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $5,691 · Current $5,691
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity:   a) Pallet Mill Area; On or about November 14, 2017 the employer exposed employees to electrical hazards in that employees were allowed to use an electrical outlet that was wired incorrectly resulting in reversing the polarity of the circuit.
Recent events (3)
  • — A (S) $5691
  • — I (S) $3000
  • — Z (S) $5691

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $5,691 · Current $5,691
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   a) Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to electrical shock hazards in that employees were allowed to use a microwave that was plugged into a 110 VAC outlet that did not have a ground.
Recent events (3)
  • — A (S) $5691
  • — I (S) $3000
  • — Z (S) $5691

1910.147 F03 II D

Repeat Gravity 5 1 instance 2 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $14,228 · Current $14,228
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:   a)  Pallet Mill; On or about November 14, 2017 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were allowed to work on the Baker 5 Head Saw together without all employees applying a personal lockout device on the energy control lockout point(s).   Southeast Forest Products, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(f)(3)(ii)(D), which was contained in OSHA inspection number 1133673, citation number 1, item number 5 and was affirmed as a final order on 5/24/2016, with respect to a workplace located at 4596 Washington Ferry Road, Montgomery AL 36108.
Recent events (3)
  • — A (R) $14228
  • — I (R) $10500
  • — Z (R) $14228

1910.305 B01 II

Repeat 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $711 · Current $711
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a)  Office Area; On or about November 14, 2017 and at times prior thereto the employer exposed employees to electrical hazards in that employees were allowed to access an ice machine that had a 110 VAC outlet box in near proximity with an unused opening not effectively closed.   Southeast Forest Products, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(f)(3)(ii)(D), which was contained in OSHA inspection number 1133673, citation number 2, item number 1 and was affirmed as a final order on 5/24/2016, with respect to a workplace located at 4596 Washington Ferry Road, Montgomery AL 36108.
Recent events (3)
  • — A (R) $711
  • — I (R) $492
  • — Z (R) $711

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Jan 25, 2018
Abate by
Feb 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:     a) Pallet Mill Area; On or about November 14, 2017 and at times prior thereto the employer exposed employees to struck-by hazards in that employees were allowed to operate a powered industrial truck without the employer ensuring that the operators had received the required evaluation at least once every three years as specified in the regulation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Southeast Forest Products Corporation's full OSHA safety record →