ATHENS, GA —
OSHA Inspection: LEON FARMER AND COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LEON FARMER AND COMPANY in 100 RAIL RIDGE ROAD P. O. BOX 1352, ATHENS, GA 30603 (NAICS 424810). OSHA activity number 342779519.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEON FARMER AND COMPANY
- Site address
- 100 RAIL RIDGE ROAD P. O. BOX 1352
- City
- ATHENS
- State
- GA
- ZIP
- 30603
- Mailing
- 100 RAIL RIDGE ROAD, ATHENS, GA 30607
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424810
- Employees
- 120
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 30, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $7,068 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards due to racks that were not bolted to the floor. On or about November 16, 2017, employees were exposed to struck-by hazards when none of the storage racks in the warehouse were bolted to the floor. Employees walk and drive powered industrial trucks in the rack aisles. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $7068
5(a)(1)
- Issued
- Mar 30, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards when damaged racks were not repaired, replaced, or taken out of service. On or about November 16, 2017, employees were exposed to struck-by hazards when the following damaged racks were in use in areas where employees load/unload product: a. location R3117 b. location R0516 c. location R6066 d. location R14032 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 A03
- Issued
- Mar 30, 2018
- Penalty
- Initial $3,604 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about November 16, 2017, the exit in the ambient room next to the roll up door was blocked with spare motorized pallet jacks. Employees store/retrieve product from the room. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $3000
- — Z (S) $3604
1910.37 B04
- Issued
- Mar 30, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $4,240 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: On or about November 16, 2017, employees were exposed to fire hazards when exit signs were not visible in the main warehouse area because the bulk storage blocked the view of the exits and exit signs along the walls. The following exits were not visible from within the main warehouse: a. exit at bulk storage b. the exit close to rack location E020 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $4000
- — Z (S) $4240
1910.38 B
- Issued
- Mar 30, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $7,068 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: On or about November 16, 2017, there was no emergency action plan for the warehouse where beer and other products are stored, received, and picked for shipment. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $4000
- — Z (S) $7068
1910.178 L04 II B
- Issued
- Mar 30, 2018
- Penalty
- Initial $8,481 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(B): Refresher training in relevant topics was not provided to the operator when the operator was involved in an accident or near-miss incident: On or about November 16, 2017, an employee involved in an accident approximately two weeks prior had not received refresher training. The employee had been disciplined but there was no plan to retrain the employee until the next plant wide training class. Employees who strike the racks, drive too fast, and do not pay attention to their surroundings are not re-trained. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $4000
- — Z (S) $8481
1910.303 G01 I A
- Issued
- Mar 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts if they were exposed or from the enclosure front or opening if they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: On or about November 16, 2017, employees were exposed to electrical hazards when the parking place for the scrubber when not in use was in front of electrical panels in the ambient room. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Leon Farmer and Company
View Leon Farmer and Company's full OSHA safety record →
More inspections in this industry (NAICS 424810)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342779519.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.