Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCGUIRE INDUSTRIES INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MCGUIRE INDUSTRIES INC. in 1.25 MILES NORTHEAST OF PYOTE, TX PATTERSON RIG #228, PYOTE, TX 79777 (NAICS 213112). OSHA activity number 342786001.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcguire Industries INC. — free Get an email when a new federal OSHA severe-injury report for Mcguire Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
1.25 MILES NORTHEAST OF PYOTE, TX PATTERSON RIG #228
City
PYOTE
State
TX
ZIP
79777
Mailing
2416 WEST 42ND ST., ODESSA, TX 79764
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
35
Ownership type
A

3 citations on file for this inspection.

1910.132 A

Other-than-serious 1 instance 2 exposed
Issued
Mar 15, 2018
Abate by
Apr 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and/or maintained in a reliable condition:  On or about November 14, 2017, the Scott Air Pack ( Model DH 2883) provided was not maintained in a reliable condition (it was not completely full). This exposed employee(s) to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02 X

Other-than-serious 1 instance 1 exposed
Issued
Mar 15, 2018
Abate by
Apr 3, 2018
Penalty
Initial $415 · Current $249 Reduced
29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:  On or about November 14, 2017, on the rig floor in the Top Dog House, the metal roof panel was partially opened in order to run electrical cables through which may cause accidental damage. This exposed employees to electric shock hazards.
Recent events (2)
  • — I (O) $249
  • — Z (O) $415

1910.334 A01

Other-than-serious 1 instance 2 exposed
Issued
Mar 15, 2018
Abate by
Apr 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation:  On or about November 14, 2017, the power cables to the H2S Monitor were hung up using metal hooks which could cause damage to the insulation. This exposed employees to electric shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mcguire Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342786001.