BEAUMONT, TX —
OSHA Inspection: MUNDY MAINTENANCE AND SERVICES LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of MUNDY MAINTENANCE AND SERVICES LLC in 11357 IH 10 AT SMITH ROAD, BEAUMONT, TX 77703 (NAICS 325212). OSHA activity number 342788700.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MUNDY MAINTENANCE AND SERVICES LLC
- Site address
- 11357 IH 10 AT SMITH ROAD
- City
- BEAUMONT
- State
- TX
- ZIP
- 77703
- Mailing
- 11150 SOUTH WILCREST DR. SUITE 300, HOUSTON, TX 77099
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325212
- Employees
- 184
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.132 D01 I
- Issued
- May 14, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $8,481 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazards identified in the hazard assessment: a) At the facility, in the 880 Budene area: On or about November 15, 2018 the employer did not ensure employees involved in line start up and fighting line fires used fire retardant protection as required in the employer's PPE requirements matrix, exposing employees to a burn hazard.
Recent events (3)
- — F (S) $0
- — C (S) $8481
- — Z (S) $8481
1910.147 C04 II C
- Issued
- May 14, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $7,068 · Current $7,068
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: a) At the facility, in the 880 Budene area: On or about November 15, 2017 the energy control procedure BMT-OP-4545, Expander Unplugging in 880, did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices and responsibility for them, exposing employees clearing plugs from inside the expander chute to a caught in hazard.
Recent events (3)
- — F (S) $7068
- — C (S) $7068
- — Z (S) $7068
1910.147 D03
- Issued
- May 14, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) At the facility, in the 880 Budene area: On or about November 15, 2018 energy isolating devices needed to control energy to the 2300 volt extruder drive motor were not located and operated to isolate the equipment from the energy source during expander unplugging, exposing employees to a caught-in hazard.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- May 14, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $7,068 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: a) At the facility, in the 880 Budene area: On or about November 15, 2017 the energy control procedure BMT-OP-4545, Expander Unplugging in 880, did not clearly and specifically outline the steps for testing a machine or equipment to determine and verify effectiveness of energy control devices, exposing employees clearing plugs from inside the expander chute to a caught in hazard.
Recent events (3)
- — F (S) $0
- — C (S) $7068
- — Z (S) $7068
1910.1200 H03 III
- Issued
- May 14, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $11,641 · Current $6,985 Reduced
8450M103M110
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: a) At the facility, 880 Budene building: On or about November 15, 2018 the employer did not provide middle operators training on procedures and work practices to protect employees from fire hazards created by chemical organic vapors during line start up operations, exposing employees to a burn hazard.
Recent events (3)
- — F (S) $6985
- — C (S) $11641
- — Z (S) $11641
1904.41 A02
- Issued
- May 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.41(a)(2): The employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form: a) For the establishment located at11357 IH 10 at Smith Road, Beaumont, Texas, Mundy Maintenance and Services LLC did not electronically submit information from their OSHA Form 300A or equivalent for calendar year 2016 by 12/15/2017. The establishment employed approximately 184 employees and is classified in NAICS 325212 during calendar year 2016.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.1051 D02 I
- Issued
- May 14, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $793 · Current $793
0410
General-duty citation text
29 CFR 1910.1051(d)(2)(i): The employer did not perform initial monitoring to determine accurately the airborne concentrations of 1,3-butadiene to which employees were exposed: a) At the facility, 880 Budene area: On or about November 21, 2017 the employer did not perform initial monitoring to determine accurately the airborne concentration of 1,3 butadiene of middle operators.
Recent events (3)
- — F (O) $793
- — C (O) $793
- — Z (O) $793
More inspections at Mundy Maintenance and Services LLC
View Mundy Maintenance and Services LLC's full OSHA safety record →
More inspections in this industry (NAICS 325212)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342788700.