On , OSHA opened a planned safety inspection of MECO ERECTION, INC. in 2545 CHARLES STREET, ROCKFORD, IL 61107 (NAICS 238120). OSHA activity number 342796174.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meco Erection, INC. — free Get an email when a new federal OSHA severe-injury report for Meco Erection, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MECO ERECTION, INC.
Site address
2545 CHARLES STREET
City
ROCKFORD
State
IL
ZIP
61107
Mailing
P.O. BOX 691, MORRIS, IL 60450
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
3
Ownership type
A

1 citation on file for this inspection.

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 29, 2018
Penalty
Initial $2,217 · Current $1,552 Reduced
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a. On or about November 29, 2017, at the above referenced worksite, employees engaged in steel erection were working from a scaffold (scissor lift). An employee left the safety of the platform by standing on the guardrail, thereby defeating the effectiveness of said guardrail. The employer failed to ensure an alternative means of fall protection was used. The employee was thereby exposed to a fall of approximately 8' to concrete surface.     There is no abatement certification of documentation required for this item.
Recent events (2)
  • — I (S) $1551.9
  • — Z (S) $2217