Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MECO ERECTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MECO ERECTION, INC. in 214 PRARIE, BATAVIA, IL 60510 (NAICS 238120). OSHA activity number 345838528.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meco Erection, INC. — free Get an email when a new federal OSHA severe-injury report for Meco Erection, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MECO ERECTION, INC.
Site address
214 PRARIE
City
BATAVIA
State
IL
ZIP
60510
Mailing
6108 GUN CLUB ROAD, MORRIS, IL 60450
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 4 exposed
Issued
May 27, 2022
Abate by
Aug 15, 2022
Penalty
Initial $7,977 · Current $5,150 Reduced
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:  On or about March 15, 2022 the employer did not instruct employees in the recognition and avoidance of unsafe conditions at the work site in a language that was understood by them.  Training was conducted in English, which was not understood by employees whose native language of Spanish.  This exposed them to hazards associated with falls and incorrectly erected scaffolding.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $5150
  • — Z (S) $7977

1926.451 A06

Serious Gravity 10 1 instance 4 exposed
Issued
May 27, 2022
Abate by
Jun 28, 2022
Penalty
Initial $11,167 · Current $7,259 Reduced
29 CFR  1926.451(a)(6):Scaffolds were not designed or erected by a qualified person:  On or about March 15, 2022 scaffolds were not designed or erected by a qualified person, exposing employees to the hazards associated with  working from a scaffold that was missing guardrails, baseplates, mud sills and did not have safe access.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $7259
  • — Z (S) $11167

1926.451 C02

Serious Gravity 5 1 instance 4 exposed
Issued
May 27, 2022
Abate by
Jun 13, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  On or about March 15, 2022 a supported scaffold was erected without mud sills or baseplates, exposing employees to the hazards associated with a scaffold collapse.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 II

Serious Gravity 5 1 instance 4 exposed
Issued
May 27, 2022
Abate by
Jun 13, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2)(ii):Unstable objects were used to support scaffolds or platform units:  On or about March 15, 2022 a supported scaffold was erected on stacked and unstable material,  exposing employees to the hazards associated with a scaffold collapse.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B01

Serious Gravity 5 1 instance 4 exposed
Issued
May 27, 2022
Abate by
Jun 13, 2022
Penalty
Initial $7,977 · Current $5,185 Reduced
29 CFR  1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  On or about March 15, 2022 scaffolds were erected without the working level being fully planked, exposing employees to a fall of approximately 15 feet.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $5185
  • — Z (S) $7977

1926.451 E01

Serious Gravity 5 1 instance 4 exposed
Issued
May 27, 2022
Abate by
Jun 13, 2022
Penalty
Initial $6,381 · Current $4,148 Reduced
29 CFR  1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  On or about March 15, 2022 a supported scaffold was erected where the point of access was greater than 2 feet, exposing employees to the hazards associated with no safe access.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $4148
  • — Z (S) $6381

1926.502 D15

Serious Gravity 10 1 instance 2 exposed
Issued
May 27, 2022
Abate by
Aug 15, 2022
Penalty
Initial $11,167 · Current $7,258 Reduced
29 CFR  1926.502(d)(15):Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:  On or about March 15, 2022 employees used a standing seam roof anchor was not capable of supporting a least 5,000 pounds per employee, exposing employees to a fall of approximately 15 feet.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $7258
  • — Z (S) $11167

View Meco Erection, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345838528.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.