Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DEPT OF AGRICULTURE - NRCS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEPT OF AGRICULTURE - NRCS in 1703 N. ELM ST., STE 2, JEFFERSON, IA 50129 (NAICS 924110). OSHA activity number 342815693.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dept of Agriculture - Nrcs — free Get an email when a new federal OSHA severe-injury report for Dept of Agriculture - Nrcs is published. One employer, no account, unsubscribe in one click.
Site address
1703 N. ELM ST., STE 2
City
JEFFERSON
State
IA
ZIP
50129
Mailing
1703 N. ELM ST., STE 2, JEFFERSON, IA 50129
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924110
Employees
3
Ownership type
D

3 citations on file for this inspection.

1910.157 E04

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 9, 2018
Abate by
May 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(4): Stored pressure dry chemical portable fire extinguishers that require a 12 year hydrostatic test were not emptied and subjected to applicable maintenance procedures every 6 years:  In the break room the Badger 5MB-6H ABC fire extinguisher had not been maintained since January of 2007.   Abatement certification is required for this violation.  The abatement certification sheet is enclosed with the notice.
Recent events (1)
  • — Z (S) $0

1910.303 E01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1)(i):  Electric equipment was used without the markings of the manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product may be identified:  In the break area an unidentifiable re-locatable power tap rated for 12 amp maximum load supplied power to a 13 amp Amana  microwave Model N-F1560W and a 1200 watt, 16amp Black and Decker Toaster Oven Model TRO390W  Corrected during inspection
Recent events (1)
  • — Z (S) $0

1910.304 B04 II B

Repeat Gravity 5 1 instance 3 exposed
Issued
Apr 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  In the break area an unidentifiable re-locatable power tap rated for 12 amp maximum load supplied power to a 13 amp Amana  microwave Model N-F1560W and a 1200 watt, 16amp Black and Decker Toaster Oven Model TRO390W.  Corrected during inspection  The US Dept. of Agriculture was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.304(b)(4)(ii)(B), which was contained in OSHA inspection number 1250360, citation number2, item number 3 and was affirmed as a final order on 9/18/2017), with respect to a workplace located a 2519 Southwest Ave., Harlan, IA 51537.
Recent events (1)
  • — Z (R) $0

View Dept of Agriculture - Nrcs's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342815693.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.