Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUNTING BEARINGS, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BUNTING BEARINGS, LLC. in 200 VAN BUREN STREET, DELTA, OH 43515 (NAICS 331528). OSHA activity number 342818333.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bunting Bearings, LLC. — free Get an email when a new federal OSHA severe-injury report for Bunting Bearings, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
200 VAN BUREN STREET
City
DELTA
State
OH
ZIP
43515
Mailing
PO BOX 37, DELTA, OH 43515
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331528
Employees
28
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 9 exposed
Issued
May 25, 2018
Abate by
Jun 13, 2018
Penalty
Initial $11,641 · Current $5,280 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to molten metal burn hazards due to the malfunctioning furnace tilt controls.    a. Bunting Bearings, LLC located in Delta, Ohio:  On or about December 1,2017 the employer did not ensure the furnace controls for #3 melting furnace were functioning properly and automatically returning to their off position when the manual initiating force is removed.  The melting furnace would slowly raise up if employees did not place a rubber band over the initiating control circuit.    b. Bunting Bearings, LLC located in Delta, Ohio:  On or about December 8, 2017 the employer did not ensure the furnace controls for #4 melting furnace were functioning properly and automatically returning to their off position when the manual initiating force is removed.  The melting furnace would slowly raise up if employees did not place a rubber band over the initiating control circuit.
Recent events (2)
  • — I (S) $5280
  • — Z (S) $11641

5(a)(1)

Serious Gravity 10 2 instances 9 exposed
Issued
May 25, 2018
Abate by
Jun 6, 2018
Penalty
Initial $11,641 · Current $5,820 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from fire and explosion hazards due to the gas line connection couplings being damaged.    a. Bunting Bearings, LLC located in Delta, Ohio:  On or about April 26, 2018 the employer did not ensure the natural gas coupling for the 3 inch supply line to the #2 tundish furnace was equipped with functioning cam locking levers to prevent the gas line from separating from the furnace.     b. Bunting Bearings, LLC located in Delta, Ohio:  On or about April 26, 2018 the employer did not ensure the natural gas coupling for the 3 inch supply line to the #6 tundish furnace was equipped with functioning cam locking levers to prevent the gas line from separating from the furnace.
Recent events (2)
  • — I (S) $5820
  • — Z (S) $11641

1910.22 A03

Serious Gravity 1 1 instance 4 exposed
Issued
May 25, 2018
Abate by
Jun 6, 2018
Penalty
Initial $4,989 · Current $2,494 Reduced
29 CFR 1910.22(a)(3): The employer did not ensure walking-working surfaces were maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.    a. Bunting Bearings, LLC located in Delta, Ohio:  On or about December 8, 2017, the employer did not ensure the walk way behind the Bruger horizontal caster, located in building #3, was free of tripping hazards.  Employees use this area to access pneumatic and water shut off valves on the caster and are exposed to the trip hazards caused by the hydraulic and water lines running across the floor.
Recent events (2)
  • — I (S) $2494
  • — Z (S) $4989

1910.178 P01

Serious Gravity 5 2 instances 1 exposed
Issued
May 25, 2018
Abate by
Jun 6, 2018
Penalty
Initial $8,315 · Current $4,157 Reduced
29 CFR 1910.178(p)(1): If at any time a powered industrial truck was found to be in need of repair, defective, or in any way unsafe, the truck was not taken out of service until it had been restored to safe operating condition.    a. Bunting Bearings, LLC located in Delta, Ohio:  On or about December 8, 2017, the employer did not ensure the Clark CGG25 forklift used in the casting department was removed from service when it was determined the horn was not functioning.    b. Bunting Bearings, LLC located in Delta, Ohio:  On or about December 8, 2017, the employer did not ensure the Mitsubishi G-M13 #25 forklift used in the casting department was removed from service when it was determined the back-up alarm was not functioning.
Recent events (2)
  • — I (S) $4157
  • — Z (S) $8315

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
May 25, 2018
Abate by
Jun 6, 2018
Penalty
Initial $11,641 · Current $5,820 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, was not guarded. The guarding device was not in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, was not so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    a. Bunting Bearings, LLC located in Delta, Ohio:  On or about April 20, 2018, the employer did not ensure the Brugger horizontal caster, located in building #3, was properly guarded in that an employee was exposed to ingoing nip points of the drive rollers when determining the rotational speed of the casting.
Recent events (2)
  • — I (S) $5820
  • — Z (S) $11641

1910.219 C03

Serious Gravity 5 1 instance 1 exposed
Issued
May 25, 2018
Abate by
Jun 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(3):  Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, was not enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section.  a. Bunting Bearings, LLC located in Delta, Ohio:  On or about April 20, 2018, the employer did not ensure the Brugger horizontal caster, located in building #3, was properly guarded in that an employee was exposed to the rotating horizontal drive shaft when determining the rotational speed of the casting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 20 exposed
Issued
May 25, 2018
Penalty
Initial $4,989 · Current $2,494 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures.    a. Bunting Bearings, LLC located in Delta, Ohio:  On or about December 8, 2017, the employer did not ensure 110 volt energized electrical wiring located in the locker room was located in an approved enclosure.
Recent events (2)
  • — I (S) $2494
  • — Z (S) $4989

View Bunting Bearings, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342818333.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.