DELTA, OH —
OSHA Inspection: BUNTING BEARINGS LLC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BUNTING BEARINGS LLC. in 200 VAN BUREN ST., DELTA, OH 43515 (NAICS 331528). OSHA activity number 342818416.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUNTING BEARINGS LLC.
- Site address
- 200 VAN BUREN ST.
- City
- DELTA
- State
- OH
- ZIP
- 43515
- Mailing
- 1001 HOLLAND PARK BLVD., HOLLAND, OH 43528
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331528
- Employees
- 28
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.28 B01 I
- Issued
- May 16, 2018
- Abate by
- Jun 7, 2018
- Penalty
- Initial $11,641 · Current $5,820 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) Bunting Bearings, Inc. located at 200 Van Buren Street in Delta, Ohio; On or about December 8, 2017 the employer did not ensure employees traveling to and from the water room located beneath the casting deck were protected from fall hazards in that the guardrails surrounding pits #4 and #5 had been removed. Employees were not utilizing any form of fall protection and were exposed to falls of approximately ten feet. b) Bunting Bearings, Inc. located at 200 Van Buren Street in Delta, Ohio; On or about April 26, 2018 the employer did not ensure employees removing steel bars from Pit #2 were protected from fall hazards. Employees removing cut steel bars from below Machine #2 were not utilizing any form of fall protection and were exposed to falls of approximately ten feet.
Recent events (2)
- — I (S) $5820
- — Z (S) $11641
1910.134 G01 I A
- Issued
- May 16, 2018
- Abate by
- May 23, 2018
- Penalty
- Initial $11,641 · Current $5,820 Reduced
1591
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: Bunting Bearings, Inc. located at 200 Van Buren Street in Delta, Ohio; On or about December 8, 2017 the employer did not ensure employees who were required to wear tight fitting elastomeric half mask respirators were clean shaven. An employee adding alloy to the furnace located on the casting deck was exposed to hazards associated with lead and metal fumes such as, but not limited to, fatigue, abdominal pains, and anemia.
Recent events (2)
- — I (S) $5820
- — Z (S) $11641
1910.146 C01
- Issued
- May 16, 2018
- Penalty
- Initial $8,315 · Current $4,157 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a) Bunting Bearings, Inc. located at 200 Van Buren Street in Delta, Ohio; On or about November 17, 2017, the employer did not ensure the workplace was evaluated to determine if any spaces were permit-required confined spaces. Employees entering the pits of the vertical centrifugal casting machine located in the centrifugal department to install the repaired vertical caster were exposed to potential hazardous atmospheres and water engulfment hazards.
Recent events (2)
- — I (S) $4157
- — Z (S) $8315
1910.146 D03
- Issued
- May 16, 2018
- Abate by
- May 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations. a) Bunting Bearings, Inc. located at 200 Van Buren Street in Delta, Ohio; On or about November 17, 2017, the employer did develop or implement procedures necessary for the safe permit space entry operations when entering the pits located beneath the vertical centrifugal casting machines located in the centrifugal department. Employees entering the pits of the vertical casting machine located in the centrifugal department to install the repaired vertical caster were exposed to potential hazardous atmospheres and water engulfment hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- May 16, 2018
- Abate by
- Jun 7, 2018
- Penalty
- Initial $11,641 · Current $5,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) Bunting Bearings, Inc. located at 200 Van Buren Street in Delta, Ohio; On or about April 20, 2018 the employer did not ensure employees were trained in the purpose and function of the energy control program. Employees were required to enter the mold holding pits located on the front of the vertical centrifugal casting machines to anchor the mold to the alignment plate. Employees were not adequately trained in the proper lock out procedures exposing them to caught in hazards from the spinning alignment plate.
Recent events (2)
- — I (S) $5820
- — Z (S) $11641
1910.147 D
- Issued
- May 16, 2018
- Abate by
- May 30, 2018
- Penalty
- Initial $11,641 · Current $5,820 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) Bunting Bearings, Inc. located at 200 Van Buren Street in Delta, Ohio; On or about April 20, 2018 employees were exposed to caught in hazards in that the vertical centrifugal casting machine located in the centrifugal department was not locked out prior to anchoring the mold to the alignment plate. The employer did not ensure that energy control application steps to control the electrical energy sources were implemented prior to setting the mold. The employer did not: - Physically operate energy isolating devices to control energy sources and affix lockout device(s). - Ensure that all potentially hazardous stored or residual energy was relieved, disconnected, and rendered safe. - Verify that isolation and de-energization of the machine or equipment had been accomplished.
Recent events (2)
- — I (S) $5820
- — Z (S) $11641
More inspections at Bunting Bearings LLC.
View Bunting Bearings LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 331528)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342818416.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.