Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AXIS RENEWABLE GROUP INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AXIS RENEWABLE GROUP INC in 15985 FM 1762, RAYMONDVILLE, TX 78580 (NAICS 333611). OSHA activity number 342820669.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Axis Renewable Group INC — free Get an email when a new federal OSHA severe-injury report for Axis Renewable Group INC is published. One employer, no account, unsubscribe in one click.
Site address
15985 FM 1762
City
RAYMONDVILLE
State
TX
ZIP
78580
Mailing
5005 TEXAS STREET, SUITE 105, SAN DIEGO, CA 92108
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333611
Employees
28
Ownership type
A

3 citations on file for this inspection.

1910.23 B09

Other-than-serious 1 instance 4 exposed
Issued
Apr 20, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.23(b)(9): Ladders were not inspected before the initial use in each work shift, or more frequently as necessary, to identify any visible defects that could cause injury:    On November 21, 2017, and times prior thereto, at the wind turbine # H2, the employer did not provide a fixed ladder free of slipping hazards, exposing employees to falls.
Recent events (2)
  • — I (O) $0
  • — Z (S) $9054

1910.29 I02

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Apr 20, 2018
Abate by
May 16, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.29(i)(2):  The connection between the carrier or lifeline and the point of attachment to the body harness or belt does not exceed 9 inches:  On November 21, 2017, and times prior thereto, at wind turbine # H2, loose carrier cable, exceeding 9 inches on a fixed ladder were utilized by employees; exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.147 D03

Other-than-serious 1 instance 4 exposed
Issued
Apr 20, 2018
Penalty
Initial $9,054 · Current $10,000
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    At the Nacelle, employees conducted maintenance services to wind turbine blades, an inadequate locking device system was used at the high speed shaft to isolate the equipment.
Recent events (2)
  • — I (O) $10000
  • — Z (S) $9054

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342820669.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.