RAYMONDVILLE, TX —
OSHA Inspection: AXIS RENEWABLE GROUP INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AXIS RENEWABLE GROUP INC in 15985 FM 1762, RAYMONDVILLE, TX 78580 (NAICS 333611). OSHA activity number 342820669.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AXIS RENEWABLE GROUP INC
- Site address
- 15985 FM 1762
- City
- RAYMONDVILLE
- State
- TX
- ZIP
- 78580
- Mailing
- 5005 TEXAS STREET, SUITE 105, SAN DIEGO, CA 92108
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333611
- Employees
- 28
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 B09
- Issued
- Apr 20, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(b)(9): Ladders were not inspected before the initial use in each work shift, or more frequently as necessary, to identify any visible defects that could cause injury: On November 21, 2017, and times prior thereto, at the wind turbine # H2, the employer did not provide a fixed ladder free of slipping hazards, exposing employees to falls.
Recent events (2)
- — I (O) $0
- — Z (S) $9054
1910.29 I02
- Issued
- Apr 20, 2018
- Abate by
- May 16, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1910.29(i)(2): The connection between the carrier or lifeline and the point of attachment to the body harness or belt does not exceed 9 inches: On November 21, 2017, and times prior thereto, at wind turbine # H2, loose carrier cable, exceeding 9 inches on a fixed ladder were utilized by employees; exposing employees to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $9054
1910.147 D03
- Issued
- Apr 20, 2018
- Penalty
- Initial $9,054 · Current $10,000
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): At the Nacelle, employees conducted maintenance services to wind turbine blades, an inadequate locking device system was used at the high speed shaft to isolate the equipment.
Recent events (2)
- — I (O) $10000
- — Z (S) $9054
More inspections in this industry (NAICS 333611)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342820669.