OSHA Inspection: BRIESS INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRIESS INDUSTRIES, INC. in 625 S. IRISH RD., CHILTON, WI 53014 (NAICS 311213). OSHA activity number 342823267.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Briess Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Briess Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
625 S. IRISH RD.
City
CHILTON
State
WI
ZIP
53014
Mailing
P.O. BOX 100, MANITOWOC, WI 54221
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311213
Employees
75
Ownership type
A

5 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 21, 2019
Penalty
Initial $13,260 · Current $13,260
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:  On or about October 16, 2017, employees were exposed to the hazard of contact with stored energy, while conducting maintenance and servicing on equipment such as but not limited to:  ball valves, check valves, and 2-way valves within the processing lines in the Brew House and Dryer Room and adequate training was not provided in accordance with the standard.
Recent events (1)
  • — Z (S) $13260

1910.147 F03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 21, 2019
Penalty
Initial $13,260 · Current $13,260
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance is performed by a crew, craft, department or other group, they shall utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device.  On or about October 16, 2017, employees were exposed to the hazard of contact with stored energy, while conducting maintenance and servicing on equipment such as but not limited to: ball valves. check valves, and 2-way valves within the processing lines in the Brew House and Dryer Room and a procedure which afforded an equivalent level of protection to personal lockout was not implemented.
Recent events (1)
  • — Z (S) $13260

1910.147 C06 I

Serious Gravity 10 1 instance 10 exposed
Issued
Feb 23, 2018
Abate by
Mar 23, 2018
Penalty
Initial $11,641 · Current $13,260
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    The employer did not conduct periodic inspections of the energy control procedures to ensure an accurate procedure and employees (such as but not limited to maintenance employees) were familiar with their responsibilities under the procedures.
Recent events (3)
  • — F (S) $13260
  • — C (S) $11641
  • — Z (S) $11641

1910.147 D

Serious Gravity 10 2 instances 10 exposed
Issued
Feb 23, 2018
Abate by
Mar 23, 2018
Penalty
Initial $0 · Current $13,260
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    Employees performing servicing and maintenance activities were not required to:  (1)  know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy,  (2)  turn off and shut down the machines  (3)  physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source,  (4)  affix lockout or tagout devices to each energy isolating device,  (5)  prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.    (a)  On or about December 3, 2017, in the Brew House, the XV3135 Utility Water Valve was removed from the pipe system while the line was energized exposing employees to being sprayed with hot water.    (b)  On or about October 13, 2017, in the Dryer Room, the RC111 2-way valve was removed from the pipe without releasing pressure in the pipe system exposing employees to being sprayed with hot water.
Recent events (3)
  • — F (S) $13260
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 10 1 instance 10 exposed
Issued
Feb 23, 2018
Abate by
Apr 13, 2018
Penalty
Initial $116,402 · Current $13,260 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     On or about October 16, 2017 and thereafter, the employer did not document and utilize energy control procedures when performing maintenance and servicing on equipment such as but not limit to: ball valves, check valves, and 2-way valves within the processing lines in the Brew House and Dryer Room.
Recent events (3)
  • — F (S) $13260
  • — C (W) $116402
  • — Z (W) $116402

View Briess Industries, INC.'s full OSHA safety record →