MARION, IL —
OSHA Inspection: US DEPARTMENT OF JUSTICE, FEDERAL BUREAU OF PRISONS, USP MARION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of US DEPARTMENT OF JUSTICE, FEDERAL BUREAU OF PRISONS, USP MARION in 4500 PRISON ROAD, MARION, IL 62959 (NAICS 922140). OSHA activity number 342835147.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 4500 PRISON ROAD
- City
- MARION
- State
- IL
- ZIP
- 62959
- Mailing
- 4500 PRISON ROAD, MARION, IL 62959
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922140
- Employees
- 476
- Ownership type
- D
Citations
2 citations on file for this inspection.
1910.147 D
- Issued
- Mar 30, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): On or about December 11, 2017, employees were exposed to machine hazards associated with moving parts during servicing and cleaning of the REED Duplimatic, Screw Injection Molding Machine located in the Potting Department of the UNICOR Factory. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Mar 30, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: In the Potting Department of the UNICOR Factory, on the REED Duplimatic, Screw Injection Molding Machine, the space above the mold was not guarded. Employees were exposed to amputation hazards.
Recent events (1)
- — Z (S) $0
More inspections at US Department of Justice, Federal Bureau of Prisons, USP Marion
View US Department of Justice, Federal Bureau of Prisons, USP Marion's full OSHA safety record →