WILLOUGHBY, OH —
OSHA Inspection: BUDZAR INDUSTRIES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BUDZAR INDUSTRIES in 38241 WILLOUGHBY PKWY, WILLOUGHBY, OH 44094 (NAICS 333415). OSHA activity number 342837812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUDZAR INDUSTRIES
- Site address
- 38241 WILLOUGHBY PKWY
- City
- WILLOUGHBY
- State
- OH
- ZIP
- 44094
- Mailing
- 38241 WILLOUGHBY PKWY, WILLOUGHBY, OH 44094
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 110
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.22 A02
- Issued
- Mar 12, 2018
- Penalty
- Initial $4,989 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): (2) The floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. When wet processes are used, drainage must be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats must be provided: On or about December 15, 2017, the machine testing area had a wet and slippery walking working surface that was cluttered with multiple water hoses and pipe fittings and wooden blocks.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.147 C01
- Issued
- Mar 12, 2018
- Penalty
- Initial $4,989 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about December 15, 2017, the employer did not have a lockout tagout program for the water testing machinery in the machine testing area of the facility.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.178 L01 I
- Issued
- Mar 12, 2018
- Penalty
- Initial $4,989 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about December 15, 2017, forklift operator employees did not receive training and evaluation.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.178 L04 II B
- Issued
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(B): Refresher training, including an evaluation of the effectiveness of that training, was not conducted as required by paragraph (l)(4)(ii) when the operator had been involved in an accident or near-miss incident to ensure that the operator had the knowledge and skills needed to operate the powered industrial truck safely; On September 25, 2017, a forklift operator employee ran over the foot of a co-worker. The employer did not provide refresher training and evaluation for the forklift operator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 G01 V
- Issued
- Mar 12, 2018
- Penalty
- Initial $4,989 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not constructed to prevent electrical shock: On or about December 15, 2017, the number 6 jib crane in the mechanical department had a pendant control that was damaged and the wiring was exposed.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.179 J02
- Issued
- Mar 12, 2018
- Penalty
- Initial $4,989 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): Overhead cranes were not inspected for defects on a daily basis for items including but not limited to; all functional operating mechanisms for maladjustment, deterioration or leakage of air or hydraulic systems and hooks: On or about December 15, 2017, the employer had 6 jib cranes that had not received a frequent and regular inspection for components such as but not limited to electrical controls, hoisting equipment, traversing structure and pedestal mountings.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.179 J03
- Issued
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: On or about December 15, 2017, the employer had 6 jib cranes that had not received a periodic inspection within the past twelve month for components such as but not limited to electrical controls, hoisting equipment, traversing structure and pedestal mountings.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 12, 2018
- Penalty
- Initial $8,315 · Current $4,989 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about December 15, 2017, the following machinery was not adequately safeguarded. 1. The Cleveland milling machine being used as a drill press had an unguarded rotating chuck. 2. The Wilton Drill press had an unguarded rotating chuck. 3. The Hyd-Mech horizontal bandsaw had 18 inches of the unused portion of the saw blade that was not guarded. 4. The Wellsaw 613 horizontal bandsaw saw blade guarding was hinged and not secured. 5. There were two Piranha ironworkers with hole punches, flat and angle stock shears that were not guarded.
Recent events (2)
- — I (S) $4989
- — Z (S) $8315
1910.212 B
- Issued
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about December 15, 2017, the Wilton drill press in the mechanical department was not anchored to the floor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Mar 12, 2018
- Penalty
- Initial $4,989 · Current $2,993 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about December 15, 2017, the employer had compressed airline nozzles being used at 50 psi for cleaning.
Recent events (2)
- — I (S) $2993.4
- — Z (S) $4989
1910.176 A
- Issued
- Mar 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(a): Permanent aisles or passageways were not appropriately marked: On or about December 15, 2017, permanent passageways and aisles for handling material with forklifts were not marked.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Budzar Industries
View Budzar Industries's full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342837812.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.