Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DOLLAR GENERAL CORPORATION, STORE #3627

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of DOLLAR GENERAL CORPORATION, STORE #3627 in 2222 TEXOMA PARKWAY, SHERMAN, TX 75090 (NAICS 452990). OSHA activity number 342838026.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dollar General Corporation, Store #3627 — free Get an email when a new federal OSHA severe-injury report for Dollar General Corporation, Store #3627 is published. One employer, no account, unsubscribe in one click.
Site address
2222 TEXOMA PARKWAY
City
SHERMAN
State
TX
ZIP
75090
Mailing
2222 TEXOMA PARKWAY, SHERMAN, TX 75090
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452990
Employees
100000
Ownership type
A

2 citations on file for this inspection.

1910.22 A01

Repeat Gravity 1 1 instance 6 exposed
Issued
Jan 8, 2018
Abate by
Feb 6, 2018
Penalty
Initial $30,487 · Current $18,292 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition.      On or about December 18, 2017, at Dollar General Store #3627, in the store aisles and break room areas, employees were exposed to hygiene, trip, slip, and fall hazards when taking breaks and/or handling merchandise without the work area being maintained in an orderly and sanitary condition.        Dollar General was previously cited for a repeat-serious violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.22(a)(1), which was contained in OSHA inspection number 1077466, citation 3, item number 001, and was affirmed as a final order on 1/22/2016, with respect to a workplace located at 2222 Texoma Parkway, Sherman, Texas 75090.    Dollar General was previously cited for a serious violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.22(a)(1), which was contained in OSHA inspection number 1092862, citation number 1, item number 1 and was affirmed as a final order on 03/26/2016, with a final abatement date on 03/15/2016, with respect to a workplace located at 203 Wedowee Street, Bowden, GA 30108.    Pursuant to 29 C.F.R. 1903, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all places of employment, passageways, storerooms or service rooms are kept clean and orderly or in a sanitary condition.
Recent events (2)
  • — I (R) $18292
  • — Z (R) $30487

1910.305 G01 IV A

Repeat Gravity 1 1 instance 6 exposed
Issued
Jan 8, 2018
Abate by
Feb 6, 2018
Penalty
Initial $30,487 · Current $6,652 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.      In the break room area, an extension cord that was run through the metal framing of the wall was used as permanent wiring to energize appliances such as but not limited to coffee pot, microwave and refrigerator exposing employees to electrical shock hazards.      Dollar General was previously cited for a serious violation of this occupational safety and health standard or its equivalent standard 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 985177, citation number 1, item number 1b and was affirmed as a final order on 07/30/2014, with respect to a final abatement date of 07/30/2014, with respect to a workplace located at 2297 Curryville Rd, Martinsburg, PA 16662.    Pursuant to 29 C.F.R. 1903, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all places of employment are free from temporary wiring used as permanent wiring.
Recent events (2)
  • — I (R) $6652
  • — Z (R) $30487

View Dollar General Corporation, Store #3627's full OSHA safety record →