DALLAS, TX —
OSHA Inspection: CTS WOOD DESIGN LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of CTS WOOD DESIGN LLC in 8221 CHANCELLOR ROW, DALLAS, TX 75247 (NAICS 337110). OSHA activity number 342840709.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CTS WOOD DESIGN LLC
- Site address
- 8221 CHANCELLOR ROW
- City
- DALLAS
- State
- TX
- ZIP
- 75247
- Mailing
- 8221 CHANCELLOR ROW, DALLAS, TX 75247
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 17
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 B05 I
- Issued
- Mar 8, 2018
- Penalty
- Initial $5,174 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained: a) In the production floor of the CTS Wood Design LLC facility where the spray booth did not have a visible gauge, audible alarm, or pressure activated device installed to ensure that the required air speed was maintained, exposing employees to fire hazards.
Recent events (2)
- — I (S) $1300
- — Z (S) $5174
1910.107 B05 IV
- Issued
- Mar 8, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) In the production floor of the CTS Wood Design LLC facility where the spray booth did not have automatic sprinklers installed, exposing employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G07
- Issued
- Mar 8, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(7): No smoking signs in large letters on contrasting color background were not conspicuously posted at all spraying areas: a) In the production floor of the CTS Wood Design LLC facility where the spraybooth did not have a No Smoking sign conspicuously posted at all spraying areas, exposing employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $3,696 · Current $950 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) In the spray booth area of the CTS Wood Design LLC facility where the employer allowed an employee to use a North half face elastomeric respirator while conducting spray finishing operations without having a written respiratory program in place.
Recent events (2)
- — I (S) $950
- — Z (S) $3696
1910.134 E01
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) In the spray booth area of the CTS Wood Design LLC facility where the employer allowed one (1) employee to use a North half face elastomeric respirator while conducting spray finishing operations without providing that employee a medical evaluation to determine that employee's fitness to wear a respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) In the spray booth area of the CTS Wood Design LLC facility where the employer allowed one (1) employee to use a North half face elastomeric respirator while conducting spray finishing operations and the employee was not required to pass a qualitative fit test or quantitative fit test.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Mar 8, 2018
- Penalty
- Initial $3,696 · Current $950 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a)) In the production area of the CTS Wood Design LLC facility where employees used compressed air at greater than 30 p.s.i. to clean wood surfaces and woodworking machines.
Recent events (2)
- — I (S) $950
- — Z (S) $3696
1910.1200 E01
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $5,174 · Current $1,300 Reduced
004004402460
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) In the spray booth area of the CTS Wood Design LLC facility where the employer did not have a written hazard communication program in place and employees used paints and sealers containing toluene, acetone, and n-butyl acetate to finish wood products.
Recent events (2)
- — I (S) $1300
- — Z (S) $5174
More inspections at CTS Wood Design LLC
View CTS Wood Design LLC's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342840709.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.