LA PORTE, TX —
OSHA Inspection: INTEGRATED POWER SERVICES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of INTEGRATED POWER SERVICES, LLC in 1500 EAST MAIN STREET, LA PORTE, TX 77571 (NAICS 335312). OSHA activity number 342849940.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTEGRATED POWER SERVICES, LLC
- Site address
- 1500 EAST MAIN STREET
- City
- LA PORTE
- State
- TX
- ZIP
- 77571
- Mailing
- 3 INDEPENDENCE PT. SUITE 100, GREENVILLE, SC 29614
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- Employees
- 72
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 A04
- Issued
- Mar 9, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $12,934 · Current $12,934
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial trucks were performed by the employer without the manufacturer's prior written approval: (a) Integrated Power Services Houston facility: On December 15, 2017 and at times prior to, the employer authorized modifications and additions which affect capacity and safe operation of a powered industrial truck (Forklift-Hyster model number H50CT, serial number B274V01731N) without the manufacturer's prior written approval or a registered engineer's written approval. This condition exposed employees to struck-by and crushing hazards.
Recent events (2)
- — I (S) $12934
- — Z (S) $12934
1910.178 L06
- Issued
- Mar 9, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $12,934 · Current $8,934 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) Integrated Power Services Houston facility: On or about December 15th 2017 and at times prior to, the employer did not certify that two employees who operate the company's power industrial truck had been trained and evaluated in accordance with OSHA regulations. This condition exposed employees to struck-by hazards.
Recent events (2)
- — I (S) $8934
- — Z (S) $12934
1904.39 A02
- Issued
- Mar 9, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $9,239 · Current $0 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report within 24 hours, the amputation of an employee's right middle and ring distal phalanges which was work-related: a) Integrated Power Services Houston facility: On September 13th 2017, an employee amputated the middle and ring distal phalanges of his right hand while working with a vertical turret lathe (S/N - 21310). The employer did not report the amputation to OSHA within 24 hours.
Recent events (2)
- — I (O) $0
- — Z (O) $9239
More inspections at Integrated Power Services, LLC
View Integrated Power Services, LLC's full OSHA safety record →
More inspections in this industry (NAICS 335312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342849940.