Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEISEL HEATING AND AIR CONDITIONING, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GEISEL HEATING AND AIR CONDITIONING, INC in 5535 WEGMAN DR, VALLEY CITY, OH 44280 (NAICS 238220). OSHA activity number 342863412.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Geisel Heating and AIR Conditioning, INC — free Get an email when a new federal OSHA severe-injury report for Geisel Heating and AIR Conditioning, INC is published. One employer, no account, unsubscribe in one click.
Site address
5535 WEGMAN DR
City
VALLEY CITY
State
OH
ZIP
44280
Mailing
633 WEST BROAD ST., ELYRIA, OH 44035
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
33
Ownership type
A

4 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 29, 2018
Penalty
Initial $7,760 · Current $4,656 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:     On or about January 4, 2018 during the maintenance of the Renzor 2.5 million BTU furnace; the employer did not ensure an employee performing maintenance operations to service/re-start the industrial furnace was properly protected from fire hazards by utilizing personal protective equipment.
Recent events (2)
  • — I (S) $4656
  • — Z (S) $7760

1910.140 C10 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 29, 2018
Penalty
Initial $7,760 · Current $4,656 Reduced
29 CFR 1910.140(c)(10)(i): (i) Directly to webbing, rope, or wire rope;    On or about January 4, 2018 during the maintenance of a an industrial furnace; the employer did not ensure employees working at height of approximately 11.3 feet above the ground were protected from a fall hazard by properly utilizing a personal fall arrest system (tied the lanyard back to itself).
Recent events (2)
  • — I (S) $4656
  • — Z (S) $7760

1910.147 C04 II B

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 29, 2018
Abate by
May 31, 2018
Penalty
Initial $6,467 · Current $2,944 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:     On or about January 4th, 2018, the employer did not ensure that the lockout tagout procedures for the Reznor 2 story, 2.5 million BTU industrial furnace; included locking out the natural gas sources.
Recent events (2)
  • — I (S) $2944
  • — Z (S) $6467

1910.147 D

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 29, 2018
Abate by
May 31, 2018
Penalty
Initial $6,467 · Current $2,944 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):      On or about January 4, 2018, the employer did not ensure employees followed lockout/tagout procedures during the service and maintenance of a Resnor 2.5 million BTU Industrial Furnace. The following was not completed:  The furnace was not shut down [per the 1910.147(d)(1) requirements], all energy sources, to include Natural Gas, were not isolated [(d)(3)] , lockout/tagout devices were not applied to each energy source to include Natural Gas  [(d)(4)], and it was not verified that the equipment energy was isolated and de-energized prior to starting work [(d)(6)].
Recent events (2)
  • — I (S) $2944
  • — Z (S) $6467

View Geisel Heating and AIR Conditioning, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342863412.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.