JERSEY CITY, NJ —
OSHA Inspection: ECUADESIGN CORP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ECUADESIGN CORP in 650 MONTGOMERY ST, JERSEY CITY, NJ 07306 (NAICS 238320). OSHA activity number 342863826.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ECUADESIGN CORP
- Site address
- 650 MONTGOMERY ST
- City
- JERSEY CITY
- State
- NJ
- ZIP
- 07306
- Mailing
- 769 MT. PROSPECT AVE, NEWARK, NJ 07104
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 G03 IV
- Issued
- Feb 26, 2018
- Penalty
- Initial $3,881 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.451(g)(3)(iv):It is impermissible for two or more vertical lifelines to be attached to each other, or to the same point of anchorage. Location: 650 Montgomery St., Jersey City, NJ. a) Two vertical life lines were attached to the same anchorage point; on or about 12/18/17.
Recent events (2)
- — I (S) $2500
- — Z (S) $3881
1926.451 D03 IX
- Issued
- Feb 26, 2018
- Penalty
- Initial $3,881 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(ix): Tiebacks were not secured to a structurally sound anchorage on the building or structure. Location: 650 Montgomery St., Jersey City, NJ. a) Tie backs were tied to the roof's guardrail system which was not structurally sound anchorage; on or about 12/18/17.
Recent events (2)
- — I (S) $2500
- — Z (S) $3881
1926.451 D03 X
- Issued
- Feb 26, 2018
- Penalty
- Initial $3,881 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle. Location: 650 Montgomery St., Jersey City, NJ. a) Tie backs were not installed perpendicular to the face of the building; on or about 12/18/17.
Recent events (2)
- — I (S) $2500
- — Z (S) $3881
More inspections at Ecuadesign Corp
View Ecuadesign Corp's full OSHA safety record →
More inspections in this industry (NAICS 238320)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342863826.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.