BILLINGS, MT —
OSHA Inspection: LITHIA CHRYSLER JEEP DODGE OF BILLINGS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LITHIA CHRYSLER JEEP DODGE OF BILLINGS in 2229 KING AVE WEST, BILLINGS, MT 59102 (NAICS 441229). OSHA activity number 342869807.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LITHIA CHRYSLER JEEP DODGE OF BILLINGS
- Site address
- 2229 KING AVE WEST
- City
- BILLINGS
- State
- MT
- ZIP
- 59102
- Mailing
- 2229 KING AVE WEST, BILLINGS, MT 59102
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441229
- Employees
- 102
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.28 B11 II
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $3,180 · Current $1,590 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails in accordance with Table D-2, Stairway Handrail Requirements: a) Lithia Chrysler Jeep Dodge of Billings, Body Shop: On or about January 10, 2017 and at times prior employees were exposed to fall hazards of 8 risers and 9 runs while accessing and egressing the parts storage area without having a standard handrail.
Recent events (2)
- — I (S) $1590
- — Z (S) $3180
1910.107 E09
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $6,236 · Current $3,118 Reduced
General-duty citation text
29 CFR 1910.107(e)(9): Flammable liquids for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity. a) Lithia Chrysler Jeep Dodge of Billings, Paint Mixing Room: On or about January 10, 2018 and at times prior employees were exposed to flash fire hazards while transferring flammable liquids such as, but not limited to, Acetone Intermediate Solvent by Cumberland Products, from the spray gun to the waste barrel without having the barrel and funnel properly bonded and grounded.
Recent events (2)
- — I (S) $3118
- — Z (S) $6236
1910.212 A01
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $4,989 · Current $2,495 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Lithia Chrysler Jeep Dodge of Billings, Auto Service Shop: On or about January 10, 2018 and at times prior employees were exposed to struck by flying chips, sparks, and debris while using an unguarded AMMCO brake lathe. b) Lithia Chrysler Jeep Dodge of Billings, Auto Service Shop: On or about January 10, 2018 and at times prior employees were exposed to struck by hazards while using an unguarded 25 Ton OTC hydraulic press to press bearings.
Recent events (2)
- — I (S) $2495
- — Z (S) $4989
1910.303 B02
- Issued
- Mar 8, 2018
- Penalty
- Initial $3,180 · Current $1,590 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Lithia Chrysler Jeep Dodge of Billings, West Wall: On January 10, 2018 and at times prior, employees were exposed to shock and fire hazards while using a relocatable power tap for permanent wiring to energize items such as, but not limited to: handheld tool chargers, computers, and other relocatable power taps.
Recent events (2)
- — I (S) $1590
- — Z (S) $3180
1910.303 B01
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Lithia Chrysler Jeep Dodge of Billings, Wash Bay: On or about January 10, 2018 and at times prior, employees were exposed to shock hazards while washing vehicles with a live wire protruding from a terminated piece of electrical conduit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Lithia Chrysler Jeep Dodge of Billings, West Wall: On or about January 10, 2018 and at times prior, employees were exposed to electrical fire hazards associated with a missing faceplate on a wall outlet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Mar 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Lithia Chrysler Jeep Dodge of Billings Automotive Repair Shop, West Wall Orange Cord: On or about January 10, 2018 and at times prior, employees were exposed to fire hazards associated with using a flexible extension cord as permanent fixed wiring. b) Lithia Chrysler Jeep Dodge of Billings Automotive Repair Shop, West Wall Blue Cord: On or about January 10, 2018 and at times prior, employees were exposed to fire hazards associated with using a flexible extension cord as permanent fixed wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 B
- Issued
- Mar 8, 2018
- Abate by
- Apr 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface. a) Lithia Chrysler Jeep Dodge of Billings, Automotive Shop: On January 10, 2018 and at times prior, the employer failed to affix a load rating on the bathroom/changing room ceiling used to store items such as, but not limited to: transfer case parts, wiring harnesses, and other automotive parts.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Lithia Chrysler Jeep Dodge of Billings
View Lithia Chrysler Jeep Dodge of Billings's full OSHA safety record →
More inspections in this industry (NAICS 441229)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342869807.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.