Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KOMPLETE GROUP, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KOMPLETE GROUP, INC. in 202 N. GREAT SOUTHWEST PKWY., GRAND PRAIRIE, TX 75050 (NAICS 326199). OSHA activity number 342871621.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Komplete Group, INC. — free Get an email when a new federal OSHA severe-injury report for Komplete Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
202 N. GREAT SOUTHWEST PKWY.
City
GRAND PRAIRIE
State
TX
ZIP
75050
Mailing
202 N. GREAT SOUTHWEST PKWY., GRAND PRAIRIE, TX 75050
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
126
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 4 instances 10 exposed
Issued
Apr 11, 2018
Abate by
May 16, 2018
Penalty
Initial $11,641 · Current $5,821 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards of being struck-by and crushed-by industrial storage racks that were causing or likely to cause death or serious physical harm to employees:     a) This violation occurred on or about January 10, 2018, and at times prior thereto; storage racks were not bolted to the floor and secured, exposing employees to the struck-by and crushed-by hazards from the storage racks collapse.    a.  Storage rack at Premier storage area.  b.  Storage rack at Kpak wall and APPC wall area.  c.  Storage rack at Kpak and Aikpak walls area.  d.  Storage rack toward compressor area.
Recent events (2)
  • — I (S) $5820.5
  • — Z (S) $11641

1910.178 L01 I

Serious Gravity 10 1 instance 7 exposed
Issued
Apr 11, 2018
Abate by
May 16, 2018
Penalty
Initial $11,641 · Current $5,821 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a)  This violation occurred on or about January 10, 2018 and at times prior thereto; when employees were operating the forklifts without having formal instruction, practical training and evaluation.
Recent events (2)
  • — I (S) $5820.5
  • — Z (S) $11641

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 11, 2018
Abate by
May 16, 2018
Penalty
Initial $6,652 · Current $3,326 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a)  In the Visual Packaging Welding/Grinding area, where employees used drill press BERGONZI, F32 without guard.
Recent events (2)
  • — I (S) $3326
  • — Z (S) $6652

1910.303 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 11, 2018
Abate by
May 16, 2018
Penalty
Initial $8,315 · Current $4,158 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    The employer did not ensure electrical equipment  is used and installed in accordance with the listing or labeling instructions.  This violation occurred on or about January 10, 2018 and at times prior thereto; in the JBOBS Laser Cutting Area:    a)  A metal junction box designed to be installed inside of a wall was used to power the HDX fan and KERD laser machine.    b)  Relocatable power tap/power strip was being used to provide power to machines and power tools.
Recent events (2)
  • — I (S) $4157.5
  • — Z (S) $8315

1910.305 B01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 11, 2018
Abate by
May 16, 2018
Penalty
Initial $8,315 · Current $4,158 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    The employer did not close unused openings on electrical equipment.  This violation occurred on or about January 10, 2018, 2013, and at times prior thereto; in the JBOBS Laser Cutting Area:    a)   A metal junction box used to provide power to HDX fan and KERD laser machine had openings at the knock-out.    b)   A metal junction box used to provide power to Heater Jet, Rigid band saw had opening at the knock-out.
Recent events (2)
  • — I (S) $4157.5
  • — Z (S) $8315

1910.305 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 11, 2018
Abate by
Apr 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a) This violation was observed on or about January 10, 2018, 2013,  in the JBOBS Laser Cutting Area; where a metal junction box was not covered.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 11, 2018
Abate by
May 16, 2018
Penalty
Initial $8,315 · Current $4,158 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) This violation occurred on or about January 10, 2018 and at times prior thereto; in the JBOBS Laser Cutting Area, where flexible cord was used as a substitute for the fixed wiring of a structure.
Recent events (2)
  • — I (S) $4157.5
  • — Z (S) $8315

1910.334 A02 II

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 11, 2018
Abate by
May 16, 2018
Penalty
Initial $8,315 · Current $4,158 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:    a)  In the Compressor area, electrical extension cords were being used had damaged insulations.     b)  In the Visual Packaging Area, flexible cord from Makita Miter saw had damaged insulation.
Recent events (2)
  • — I (S) $4157.5
  • — Z (S) $8315

View Komplete Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342871621.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.