OSHA Inspection: TURBINEAERO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TURBINEAERO INC. in 6520 W. WILLIS ROAD, CHANDLER, AZ 85226 (NAICS 332812). OSHA activity number 342872983.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Turbineaero INC. — free Get an email when a new federal OSHA severe-injury report for Turbineaero INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TURBINEAERO INC.
Site address
6520 W. WILLIS ROAD
City
CHANDLER
State
AZ
ZIP
85226
Mailing
6520 W. WILLIS ROAD, CHANDLER, AZ 85226
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
18
Ownership type
A

9 citations on file for this inspection.

1910.146 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2018
Abate by
Mar 9, 2018
Penalty
Initial $8,315 · Current $7,000 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    TurbineAero Chandler: The pit inside the Fluoride Ion Cleaning (FIC) room  has argon and hydrogen fluoride gas lines connected to the vacuum furnaces. Employer failed to correctly evaluate the space for a hazardous atmosphere.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $8315

1910.146 C04

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2018
Abate by
Mar 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  TurbineAero Chandler: The employer did not develop and implement a written permit space entry program for employees assigned to perform maintenance activities under the vacuum furnaces inside the Fluoride Ion Cleaning room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 14 exposed
Issued
Feb 27, 2018
Abate by
Mar 9, 2018
Penalty
Initial $8,315 · Current $5,000 Reduced
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift:    TurbineAero Chandler: The employer failed to ensure the powered industrial truck, which was used round-the-clock basis was examined on a shift by shift basis. The only inspections that were found to be performed were at the start of the first shift on weekdays. The strobe light on top of the roof was inoperable.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $8315

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2018
Penalty
Initial $8,315 · Current $5,000 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    Maintenance Shop - The work rest installed on the United 8-inch bench grinder was not properly adjusted to prevent the work from being jammed between the wheel and work rest which may cause wheel breakage. The work rest measured 1/4 inch away from the wheel on the right side.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $8315

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2018
Penalty
Initial $8,315 · Current $4,000 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    Maintenance Shop - The tongue guard on the United 8-inch bench grinder was not properly adjusted to protect against wheel breakage. The tongue guard measured 1-inch from the wheel on the right side.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $8315

1910.242 B

Serious Gravity 5 2 instances 4 exposed
Issued
Feb 27, 2018
Abate by
Mar 9, 2018
Penalty
Initial $8,315 · Current $5,000 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a) Located in the Laboratory room, compressed air was being used by employees for cleaning purposes with air pressure exceeding 60 p.s.i.    b) Located in the Electroplating room, compressed air was being used by employees for cleaning purposes with air pressure exceeding 60 p.s.i.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $8315

1910.243 B02

Serious Gravity 5 2 instances 4 exposed
Issued
Feb 27, 2018
Abate by
Mar 9, 2018
Penalty
Initial $6,652 · Current $4,000 Reduced
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected.    a. Located in the Laboratory, there was an airhose that was used in part to supply air to a pneumatic needle gun. The airhose was attached to the hose fitting by a worm drive type clamp which was not designed for use on an airhose, thereby exposing the employees to the whipping action of the hose if the clamp were to come off.     b. Located in the Electroplating room, there was an airhose that was used in part to supply air to a pneumatic needle gun. The airhose was attached to the hose fitting by a worm drive type clamp which was not designed for use on an airhose, thereby exposing the employees to the whipping action of the hose if the clamp were to come off.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6652

1910.305 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2018
Abate by
Mar 9, 2018
Penalty
Initial $8,315 · Current $5,000 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    Outdoor Water Heater - The 4 inch by 4 inch junction box cover for the water heater located by the chemical stripping room outside, was not provided with a cover.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $8315

1910.305 G01 IV A

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 27, 2018
Abate by
Mar 9, 2018
Penalty
Initial $4,989 · Current $3,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    Vacuum Furnace Room: A flexible cord approximately 100 foot connected to a fan was used as a substitute for fixed wiring.