HORTONVILLE, WI —
OSHA Inspection: SKIDS, CRATES, & PALLETS INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SKIDS, CRATES, & PALLETS INCORPORATED in 1010 CORPORATION DRIVE, HORTONVILLE, WI 54944 (NAICS 321920). OSHA activity number 342876091.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SKIDS, CRATES, & PALLETS INCORPORATED
- Site address
- 1010 CORPORATION DRIVE
- City
- HORTONVILLE
- State
- WI
- ZIP
- 54944
- Mailing
- PO BOX 416, HORTONVILLE, WI 54944
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 45
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 29, 2018
- Abate by
- Apr 26, 2018
- Penalty
- Initial $5,497 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. On or about January 10, 2018, a Pacific Trail Mfg., Inc. Accu-Cut crosscut saw did not have a lockout tagout procedure developed, documented, and utilized when employees were engaged in servicing and maintenance work. Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $5497
1910.147 D03
- Issued
- Mar 29, 2018
- Penalty
- Initial $0 · Current $3,298
General-duty citation text
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). On or about February 7, 2018, a Pacific Trail Mfg., Inc. Accu-Cut crosscut electrical disconnect located in the control panel was not functioning properly and would not isolate the machine as required for lockout tagout.
Recent events (2)
- — I (S) $3298.2
- — Z (S) $0
1910.147 C07 I A
- Issued
- Mar 29, 2018
- Abate by
- Apr 26, 2018
- Penalty
- Initial $5,497 · Current $3,298 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. On or about January 10, 2018, an employee operating the Pallet Repair Systems, Inc. pallet dismantler was not provided training in the company's energy control program when performing servicing and maintenance work on the equipment such as changing blades.
Recent events (2)
- — I (S) $3298.2
- — Z (S) $5497
1910.212 A01
- Issued
- Mar 29, 2018
- Penalty
- Initial $4,398 · Current $2,639 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. (a) On or about January 10, 2018, employees were exposed to crushed by hazards when reaching into an Automated Industrial Technologies Auto Stacker that had the guard removed. (b) On or about January 10, 2018, employees were exposed to struck by hazards from a pallet flipper on a Viking Turbo Model 505 pallet assembly machine located in the assembly department that had expanded metal guards with sections cut out.
Recent events (2)
- — I (S) $2638.8
- — Z (S) $4398
1910.212 A02
- Issued
- Mar 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. (a) On or about January 10, 2018, a Cornell chop saw located in the hardwoods department had broken expanded metal guards which were not securely affixed to the machine creating sharp edges which resulted in laceration hazards to employees. (b) On or about January 10, 2018, a Viking Turbo Model 505 pallet assembly machine located in the assembly department had expanded metal guards with sections cut out creating sharp edges which resulted in laceration hazards to employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 A09
- Issued
- Mar 29, 2018
- Penalty
- Initial $5,497 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts shall be guarded in accordance with the specific requirements of 1910.219. On or about January 10, 2018, a Cornell chop saw located in the hardwoods department did not have the drive belt and pulley under seven feet from the floor guarded as required in 29 CFR 1910.219(d)(1) and (e)(3)(iii). The guard in placed extended approximately 6 feet 5.5 inches from the floor.
Recent events (2)
- — I (O) $1000
- — Z (S) $5497
1910.213 R04
- Issued
- Mar 29, 2018
- Abate by
- Jun 1, 2018
- Penalty
- Initial $5,497 · Current $3,298 Reduced
General-duty citation text
29 CFR 1910.213(r)(4): The mention of specific machines in paragraphs (a) thru (q) and this paragraph (r) of this section, inclusive, is not intended to exclude other woodworking machines from the requirement that suitable guards and exhaust hoods be provided to reduce to a minimum the hazard due to the point of operation of such machines. On or about January 10, 2018, a Pacific Trail Mfg., Inc. Accu-Cut Crosscut saw did not have the point of operation guarded to prevent employees from accessing it during operation.
Recent events (2)
- — I (S) $3298.2
- — Z (S) $5497
1910.305 G01 IV
- Issued
- Mar 29, 2018
- Penalty
- Initial $5,497 · Current $3,298 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for fixed wiring of a structure; where run through holes in walls, ceilings, or floors; where run through doorways, windows, or similar openings; where attached to building surfaces; where concealed behind building walls, ceilings, or floors; or where installed in raceways, except as otherwise permitted in this subpart. (a) On or about January 10, 2018, a flexible extension cord located near the knotcher and re-saw was used as fixed wiring to power a fan and attached with zip ties to the building structure. (b) On or about January 10, 2018, a flexible extension cord located near the pallet dismantler was used as fixed wiring to power fans and was concealed behind equipment.
Recent events (2)
- — I (S) $3298.2
- — Z (S) $5497
More inspections at Skids, Crates, & Pallets Incorporated
View Skids, Crates, & Pallets Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342876091.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.