TOLEDO, OH —
OSHA Inspection: ALLIED MASK & TOOLING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALLIED MASK & TOOLING, INC. in 6051 TELEGRAPH ROAD SUITE #6, TOLEDO, OH 43612 (NAICS 332999). OSHA activity number 342884053.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLIED MASK & TOOLING, INC.
- Site address
- 6051 TELEGRAPH ROAD SUITE #6
- City
- TOLEDO
- State
- OH
- ZIP
- 43612
- Mailing
- 6051 TELEGRAPH ROAD SUITE #6, TOLEDO, OH 43612
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.28 B01 I A
- Issued
- Mar 14, 2018
- Abate by
- Mar 23, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a standard guardrail system. a. On or about January 18, 2018, in the main shop, an open-sided platform was not protected by a guardrail along multiple sections of the storage area located along the north side of the main shop there by exposing employees to a fall hazard of more than eight feet. b. On or about January 18, 2018, in the main shop, a platform was not protected by a standard guardrail system in that lattice was used in place of a midrail along a portion of the storage area there by exposing employees to a fall hazard of more than eight feet. c. On or about January 18, 2018, in the main shop, an open-sided platform used to transition from the storage area to the top of work cells was not protected by a guardrail there by exposing employees to a fall hazard of more than eight feet. d. On or about January 18, 2018, in the main shop, an open-sided platform used for storage above individual work cells #5 and #6 was not protected by a guardrail there by exposing employees to a fall hazard of more than eight feet.
Recent events (1)
- — Z (S) $3880
1910.28 B11 II
- Issued
- Mar 14, 2018
- Abate by
- Mar 23, 2018
- Penalty
- Initial $2,772 · Current $2,772
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as follows: On or about January 18, 2018, in the main shop storage area, an open stairway with 15 risers leading to the storage area was not provided with a stair rail system that included a midrail thereby exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $2772
1910.37 A03
- Issued
- Mar 14, 2018
- Abate by
- Mar 23, 2018
- Penalty
- Initial $2,217 · Current $2,217
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about January 18, 2018, in the main shop storage area, three empty oxygen cylinders were placed in front of the exit door thereby blocking exit routes in the event of an emergency.
Recent events (1)
- — Z (S) $2217
1910.101 B
- Issued
- Mar 14, 2018
- Abate by
- Mar 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a. On or about January 18, 2018, in the main shop storage area, near the fire exit door, ten compressed gas cylinders were not properly secured or supported to prevent the cylinder from falling, thereby exposing employees to a struck by hazard. b. On or about January 18, 2018, in the main shop storage area, near work cell #5, one compressed Argon gas cylinder was not properly secured or supported to prevent the cylinder from falling, thereby exposing employees to a struck by hazard.
Recent events (1)
- — Z (S) $0
1910.303 B08 I
- Issued
- Mar 14, 2018
- Abate by
- Mar 23, 2018
- Penalty
- Initial $2,217 · Current $2,217
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted: On or about January 18, 2018, in the main shop, the employer did not ensure that a four way electrical outlet box used to provide power to a sandblaster fluorescent light was secured to any surface there by exposing employees to an electrical hazard.
Recent events (1)
- — Z (S) $2217
1910.305 B01 II
- Issued
- Mar 14, 2018
- Abate by
- Mar 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: The employer failed to ensure unused openings in boxes and cabinets were effectively closed: a. On or about January 18, 2018, in the main shop, the employer did not ensure eight openings in circuit breaker panel were covered, there by exposing employees to a shock and or fire hazard. Additionally, three opening (knockouts) on the left side of the panel were not effectively closed. b. On or about January 18, 2018, in the main shop, one unused opening (knockout) in a four way electrical box was covered, there by exposing employees to a shock and or fire hazard.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Mar 14, 2018
- Abate by
- Apr 6, 2018
- Penalty
- Initial $2,217 · Current $2,217
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about January 18, 2018, in the main shop, the employer used flexible cable as a substitute for fixed wiring in that a flexible cord was used to power a four way outlet which provided power to an sandblaster fluorescent light there by exposing employees to an electrical hazard. b. On or about January 18, 2018, in the main shop, the employer used flexible cable as a substitute for fixed wiring in that a flexible cord was used to power various pieces of equipment such as but not limited to the Lincoln electric Tig Welders there by exposing employees to an electrical hazard.
Recent events (1)
- — Z (S) $2217
More inspections at Allied Mask & Tooling, INC.
View Allied Mask & Tooling, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342884053.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.