WICHITA, KS —
OSHA Inspection: SINCLAIR & SONS CUSTOM WELDING & MACHINING SERVICE INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SINCLAIR & SONS CUSTOM WELDING & MACHINING SERVICE INC in 1023 SOUTH SANTE FE, WICHITA, KS 67211 (NAICS 332710). OSHA activity number 342884202.
Where did this inspection happen?
- Site address
- 1023 SOUTH SANTE FE
- City
- WICHITA
- State
- KS
- ZIP
- 67211
- Mailing
- 1023 SOUTH SANTE FE, WICHITA, KS 67211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 22
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.305 G02 III
- Issued
- Penalty
- Initial $1696.00 · Current $1187.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Employees engaged in machining activities in the mill shop were exposed to electrical shock hazards in that the strain relief for flexible power cords was not provided in the following instances: 1.) Bridgeport Machines Inc. Serial number J324926 2.) Bridgeport Machines Inc. Serial number J14072
Recent events (2)
- — I (S) $1187.2
- — Z (S) $1696
1910.334 A02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Employees engaged in machining activities in the mill shop were exposed to electrical shock hazards in the following instances, in that equipment was not visually inspected for damage before use: 1.) Bridgeport Machines Inc. Serial number J324926, damage to out jacket of power cord 2.) Bridgeport Machines Inc. Serial number J14072 , damage to outer jacket of power cord
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at SINCLAIR & SONS CUSTOM WELDING & MACHINING SERVICE INC
WICHITA, KS—2026-01-28
SINCLAIR & SONS CUSTOM WELDING & MACHINING SERVICE INC
WICHITA, KS—2014-11-04 00:00:00
SINCLAIR & SONS CUSTOM WELDING & MACHINING SERVICE INC
WICHITA, KS—2014-04-22 00:00:00
SINCLAIR & SONS CUSTOM WELDING & MACHINING SERVICE INC
View SINCLAIR & SONS CUSTOM WELDING & MACHINING SERVICE INC's full OSHA safety record →
More inspections in this industry (NAICS 332710)
CAMBRIDGE, MN—2026-07-09
111567 - VISION MACHINE INC
SAINT PAUL, MN—2026-07-09
111558 - ST PAUL MACHINE - DESIGN INC
EVERETT, WA—2026-07-07
WA317991968 - ONOMAC INDUSTRIES INC
SOUTH DEERFIELD, MA—2026-07-07
VISION MACHINING INC
LAKEVILLE, MN—2026-07-02
111518 - KD HOLDING COMPANY INC DBA MEDFAB MANUFACTURING CO
More inspections in KS
WICHITA, KS—2026-07-10
DIVERSIFIED SERVICES, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
WICHITA, KS—2026-07-09
FIGEAC AERO NORTH AMERICA, INC.
PITTSBURG, KS—2026-07-08
CDL ELECTRIC
WICHITA, KS—2026-07-08
IBT, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342884202.