JACKSONVILLE, FL —
OSHA Inspection: ALLEGIANCE ROOF SYSTEMS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALLEGIANCE ROOF SYSTEMS, LLC in 643 LUCENTE DRIVE, JACKSONVILLE, FL 32210 (NAICS 238160). OSHA activity number 342903028.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLEGIANCE ROOF SYSTEMS, LLC
- Site address
- 643 LUCENTE DRIVE
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32210
- Mailing
- 3968 PRITMORE ROAD, JACKSONVILLE, FL 32257
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Feb 21, 2018
- Abate by
- Mar 1, 2018
- Penalty
- Initial $2,956 · Current $1,752 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a. On or about January 26, 2018, employees operating nail guns and a saw were not wearing eye protection being exposed to eye injuries from flying debris.
Recent events (2)
- — I (S) $1752.2
- — Z (S) $2956
1926.501 B13
- Issued
- Feb 21, 2018
- Penalty
- Initial $3,696 · Current $2,218 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On or about January 26, 2018, employees installing roof shingles on a 1:12 pitch roof were not protected from falling 9 to the ground by a fall protection system.
Recent events (2)
- — I (S) $2217.6
- — Z (S) $3696
1926.1053 B01
- Issued
- Feb 21, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about January 26, 2018, employees were using a Werner 14-foot extension ladder to access the roof that was extended one rung above the landing and was not tied off to prevent accidental displacement, exposing employees to a 9 feet fall hazard.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
More inspections at Allegiance Roof Systems, LLC
View Allegiance Roof Systems, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342903028.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.