NATCHEZ, MS —
OSHA Inspection: BLUFF CITY BOWL
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BLUFF CITY BOWL in 285 JOHN R. JUNKIN DR., NATCHEZ, MS 39120 (NAICS 713950). OSHA activity number 342918612.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BLUFF CITY BOWL
- Site address
- 285 JOHN R. JUNKIN DR.
- City
- NATCHEZ
- State
- MS
- ZIP
- 39120
- Mailing
- 285 JOHN R. JUNKIN DR., NATCHEZ, MS 39120
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713950
- Employees
- 13
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.141 A03 II
- Issued
- Mar 30, 2018
- Abate by
- May 14, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.141(a)(3)(ii): The floor of every workroom shall be maintained, so far as practicable, in a dry condition. Where wet processes are used, drainage shall be maintained and false floors, platforms, mats, or other dry standing places shall be provided, where practicable, or appropriate waterproof footgear shall be provided. (a) Walkway beside Lane 16 and the warehouse - On or about January 30, 2018 employees were exposed to a potential fall hazard due to water leaking from the roof onto the floor.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.303 F02
- Issued
- Mar 30, 2018
- Abate by
- May 14, 2018
- Penalty
- Initial $2,956 · Current $1,774 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. (a) Circuit breaker panel near the back roll up door - On or about January 30, 2018 employees were exposed to a potential electrical shock hazard and fire hazard due to a circuit breaker box not being labeled for emergency shut-off.
Recent events (2)
- — I (S) $1773.6
- — Z (S) $2956
1910.303 G02 I
- Issued
- Mar 30, 2018
- Abate by
- May 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: (a) Circuit breaker panel near the back roll up door - On or about January 30, 2018 an employee was exposed to a potential electrical shock hazard and fire hazard due to a circuit breaker box having exposed live electrical parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0