GREEN BAY, WI —
OSHA Inspection: PIONEER METAL FINISHING CORP.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PIONEER METAL FINISHING CORP. in 486 GLOBE AVENUE, GREEN BAY, WI 54304 (NAICS 332813). OSHA activity number 342921236.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PIONEER METAL FINISHING CORP.
- Site address
- 486 GLOBE AVENUE
- City
- GREEN BAY
- State
- WI
- ZIP
- 54304
- Mailing
- 486 GLOBE AVENUE, GREEN BAY, WI 54304
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 265
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.124 J01
- Issued
- Apr 13, 2018
- Abate by
- May 11, 2018
- Penalty
- Initial $6,912 · Current $4,147 Reduced
General-duty citation text
29 CFR 1910.124(j)(1): You must inspect the hoods and ductwork of the ventilation system for corrosion or damage: At least quarterly during operation and prior to operation after a prolonged shutdown: A) On or about February 1, 2018, the employer had not developed and implemented an inspection procedure for the hoods and ductwork of the ventilation systems associated with the 450 and 850 Electroless Nickel Process Lines dip tanks.
Recent events (2)
- — I (S) $4147.2
- — Z (S) $6912
1910.124 J02
- Issued
- Apr 13, 2018
- Abate by
- May 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.124(j)(2): You must ensure that the airflow is adequate: At least quarterly during operation and prior to operation after a prolonged shutdown: A) On or about February 1, 2018, the employer had not developed and implemented an inspection procedure of the ventilation systems associated with the 450 and 850 Electroless Nickel Process Lines dip tanks to ensure the airflow is adequate.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Pioneer Metal Finishing Corp.
View Pioneer Metal Finishing Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342921236.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.