Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: YUMA ETHANOL, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of YUMA ETHANOL, LLC in 38480 CR H, YUMA, CO 80759 (NAICS 325193). OSHA activity number 342924586.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Yuma Ethanol, LLC — free Get an email when a new federal OSHA severe-injury report for Yuma Ethanol, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
YUMA ETHANOL, LLC
Site address
38480 CR H
City
YUMA
State
CO
ZIP
80759
Mailing
38480 CR H, YUMA, CO 80759
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325193
Employees
28
Ownership type
A

3 citations on file for this inspection.

1910.119 J04 I

Serious Gravity 5 1 instance 28 exposed
Issued
Jul 13, 2018
Abate by
Aug 29, 2018
Penalty
Initial $6,467 · Current $3,800 Reduced
29 CFR 1910.119(j)(4)(i): Inspections and tests were not performed on process equipment:    a)       Yuma Ethanol, LLC at 38480 CR H, Yuma, CO, 80759: On or about 1/30/2018 the employer did not perform inspections and tests on process equipment. Where PSM is applicable, the employer must ensure that process equipment is inspected and tested per Recognized and Generally Accepted Good Engineering Practices (RAGAGEP). A system utilizing approximately 18,000 gallons (95,026 pounds) of anhydrous ammonia was used to alter the pH of corn slurry within a process tank inside of the production building. The process tank was not inspected and tested at a frequency set forth by RAGAGEP. This condition exposed employees to chemical and burn hazards.
Recent events (2)
  • — I (S) $3800
  • — Z (S) $6467

1910.119 J05

Serious Gravity 5 1 instance 28 exposed
Issued
Jul 13, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.119(j)(5): Equipment deficiencies. The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information in paragraph (d) of this section) before further use or in a safe and timely manner when necessary means were taken to assure safe operation:  (a)   Yuma Ethanol, LLC at 38480 CR H, Yuma, CO, 80759: On or about 1/30/2018 the employer did not correct deficiencies in equipment that were outside acceptable limits before further use or in a safe and timely manner. Where PSM is applicable, the employer must ensure that process equipment is inspected and tested per Recognized and Generally Accepted Good Engineering Practices (RAGAGEP). After process equipment is inspected and tested, the employer must ensure that deficiencies in equipment that were outside acceptable limits are corrected before further use or in a safe and timely manner. A system utilizing approximately 18,000 gallons (95,026 pounds) of anhydrous ammonia was used to alter the pH of corn slurry within a process tank inside of the production building. A process tank holding corn slurry was identified as having deficient insulation in a mechanical integrity report conducted in 2012. The employer had still not adequately corrected the deficiencies during the time of the inspection in 2018. This condition exposed employees to chemical and burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 B03 I

Other-than-serious 1 instance 28 exposed
Issued
Jul 13, 2018
Abate by
Aug 29, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(b)(3)(i): The employer did not ensure that labels on incoming containers of hazardous chemicals are not removed or defaced:  a)       Yuma Ethanol, LLC at 38480 CR H, Yuma, CO, 80759: On or about 1/30/2018 the employer did not ensure that labels on incoming containers of hazardous chemicals were not removed or defaced. On 1/30/2018, a 1249 liter capacity container full of 10% sodium hypochlorite was observed in the chemical storage area with a torn label. Employees use the sodium hypochlorite in sanitizing and other operations at an ethanol production facility. This condition exposed employees to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Yuma Ethanol, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342924586.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.