WINDSOR, CO —
OSHA Inspection: HEXCEL CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of HEXCEL CORPORATION in 31815 GREAT WESTERN DRIVE, WINDSOR, CO 80550 (NAICS 313320). OSHA activity number 342927365.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEXCEL CORPORATION
- Site address
- 31815 GREAT WESTERN DRIVE
- City
- WINDSOR
- State
- CO
- ZIP
- 80550
- Mailing
- 31815 GREAT WESTERN DRIVE, WINDSOR, CO 80550
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 313320
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 C02 I
- Issued
- Apr 3, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (a) Hexcel Corporation at 31815 Great Western Drive, Windsor, CO: On or before February 5, 2018, the employer did not ensure that any employee using a respirator voluntarily was provided with the information contained in Appendix D to this section when the employer determined that any voluntary respirator use was permissible. The employer provided 3M Model 8210 N95 filtering face piece respirators for voluntary use. This condition exposed the employees to a respiratory hazard.
Recent events (1)
- — Z (O) $0
1910.1200 G08
- Issued
- Apr 3, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical: (a) Hexcel Corporation at 31815 Great Western Drive, Windsor, CO: On and before February 5, 2018, the employer did not ensure that material safety data sheets were updated to safety data sheets for each hazardous chemical in the workplace, including, but not limited to, acetone, Dyhard A5M30, tetrahydrofurfuryl alcohol, and KFR-136SLH.
Recent events (1)
- — Z (O) $0
More inspections at Hexcel Corporation
View Hexcel Corporation's full OSHA safety record →
More inspections in this industry (NAICS 313320)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342927365.