HOLLAND, MI —
OSHA Inspection: YACHT BASIN CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of YACHT BASIN CORPORATION in 1866 OTTAWA BEACH, HOLLAND, MI 49424 (NAICS 713930). OSHA activity number 342936556.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YACHT BASIN CORPORATION
- Site address
- 1866 OTTAWA BEACH
- City
- HOLLAND
- State
- MI
- ZIP
- 49424
- Mailing
- 1866 OTTAWA BEACH, HOLLAND, MI 49424
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713930
- Employees
- 21
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.28 B11 II
- Issued
- Mar 9, 2018
- Penalty
- Initial $2,217 · Current $1,109 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as follows: a. On or about February 8, 2018, in the Building 1, an enclosed stairway leading up to the furnace with 12 risers was not provide with a handrail thereby exposing employees to a fall hazard. b. On or about February 8, 2018, in the Building 1, an enclosed stairway leading up to a storage mezzanine with 18 risers was not provide with a handrail thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $1109
- — Z (S) $2217
1910.37 B02
- Issued
- Mar 9, 2018
- Penalty
- Initial $2,956 · Current $1,478 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a. On or about February 8, 2018, in the shop on the north side, the exit leading out of the building was not marked by a sign reading "Exit". b. On or about February 8, 2018, in the shop on the south side, the exit leading out of the building was not marked by a sign reading "Exit".
Recent events (2)
- — I (S) $1478
- — Z (S) $2956
1910.242 B
- Issued
- Mar 9, 2018
- Penalty
- Initial $2,956 · Current $1,478 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about February 8, 2018, in the shop, the employer did not reduced the air pressure to 30 p.s.i. on air nozzles used for cleaning parts and for cleaning an employees body and clothing. The air pressure was set at approximately 150 p.s.i., there by exposing employees to a struck by or air embolism hazards.
Recent events (2)
- — I (S) $1478
- — Z (S) $2956
1910.303 B02
- Issued
- Mar 9, 2018
- Penalty
- Initial $2,217 · Current $1,108 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about February 8, 2018, adjacent to a workbench located on the south side of the building, the employer did not ensure that a relocatable power tap was not daisy chained to an orange extension cord to provide power to a two bulb florescent light and a four way outlet there by exposing an employee to an electrical shock hazard.
Recent events (2)
- — I (S) $1108
- — Z (S) $2217
1910.303 B08 I
- Issued
- Mar 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted: On or about February 8, 2018, in the shop, the employer did not ensure that four way electrical outlet box used to provide power to a parts washer was firmly secured to the workbench there by exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Mar 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about February 8, 2018, in the shop, a electrical cord of a 16" Craftsman Direct Drive Scroll Saw had a missing ground plug and did not have a continuous ground there by exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Mar 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about February 8, 2018, adjacent to a workbench located on the south side of the building, the employer used flexible cable as a substitute for fixed wiring in that the flexible cords were used provide power to a two bulb florescent light, parts washer and a four way outlet there by exposing an employee to an electrical hazard. b. On or about February 8, 2018, in the main shop, the employer used flexible cable as a substitute for fixed wiring in that a flexible cord was used to power various pieces of equipment such as but not limited to: 16" Craftsman Scroll saw, DeWalt miter saw and four way outlet there by exposing employees to an electrical hazard. c. On or about February 8, 2018, in the main shop, the employer used flexible cable as a substitute for fixed wiring in that a flexible cord was used to power 220v Delta table saw there by exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Mar 9, 2018
- Abate by
- Mar 28, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about February 8, 2018, The employer did not develop a lock out / tag-out program to control and isolate hazardous energy exposing employees to mechanical and electrical energy hazards while performing servicing and/or maintenance work on machines or equipment such as but not limited to 16 " Craftman Scroll saw, Delta Table Saw Dewalt Miter Saw and various band saws.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Mar 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about February 18, 2018, in the shop, The employer failed to ensure unused opening (knockout) in a electrical box located on top of the air compressor was covered, there by exposing employees to a shock and or fire hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Yacht Basin Corporation
View Yacht Basin Corporation's full OSHA safety record →
More inspections in this industry (NAICS 713930)
More inspections in MI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342936556.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.