MORTON, IL —
OSHA Inspection: MATCOR METAL FABRICATION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MATCOR METAL FABRICATION, INC. in 1021 W BIRCHWOOD ST, MORTON, IL 61550 (NAICS 332322). OSHA activity number 342951878.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MATCOR METAL FABRICATION, INC.
- Site address
- 1021 W BIRCHWOOD ST
- City
- MORTON
- State
- IL
- ZIP
- 61550
- Mailing
- 1021 W BIRCHWOOD ST, MORTON, IL 61550
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 394
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $10,163 · Current $10,163
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about February 13, 2018, employees were required to perform servicing and maintenance activities on equipment, such as, but not limited to, vertical spindle machining centers and milling machines, and the lockout procedures did not address all potentially hazardous energy sources.
Recent events (2)
- — I (S) $10163
- — Z (S) $10163
1910.147 C04 II C
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: On or about February 13, 2018, employees were required to perform servicing and maintenance activities on equipment, such as, but not limited to, vertical spindle machining centers and milling machines, and the lockout procedures did not address the requirements for placement, removal and transfer of the lockout devices.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: On or about February 13, 2018, employees were required to perform servicing and maintenance activities on equipment, such as, but not limited to, vertical spindle machining centers and milling machines, and the lockout procedures did not address the requirements for testing and verifying the effectiveness of the lockout devices.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: On or about February 13, 2018, employees were required to perform lockout/tagout procedures and an annual inspection of the energy control procedures had not been conducted.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $10,163 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedures for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): On or about February 13, 2018, employees were exposed to the unexpected energization of the Mitsui Seiki VS5Q Vertical Spindle Machining Center, Model Number VS5Q, Serial Number 308, while conducting servicing and maintenance activities such as changing the bits/tooling. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $10163
1910.178 L04 III
- Issued
- Jun 15, 2018
- Penalty
- Initial $8,130 · Current $8,130
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years: On or about May 9, 2018, the employer had not conducted an evaluation of a powered industrial truck operator's performance once every three years.
Recent events (2)
- — I (S) $8130
- — Z (S) $8130
1910.212 A01
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $12,934 · Current $10,163 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about February 13, 2018, employees working in: a. the Tool Room were exposed to the hazard of being caught in rotating parts while operating the 600 Lathes Ltd Vertical Lathe, Model Number Alpha 400, Serial Number A30167, because the employer had not provided adequate machine guarding. b. the Tool Room were exposed to the hazard of being caught in rotating parts while operating the vertical belt sander on the left and right sides of the Hammond Abrasive Vertical Belt Grinder, Machine Number M-471, Model Number UBG-62-6S, Serial Number 1431, because the employer had not provided adequate machine guarding. c. NPI (New Product Introduction) were exposed to the hazard of being struck by and crushed by inadvertent contact with the Wysong Shear, Machine Number M-28, Model Number 1251, when accessing the area behind the shear to retrieve stored materials.
Recent events (2)
- — I (S) $10163
- — Z (S) $12934
1910.212 A03 II
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury was not guarded: On or about February 13, 2018, an employee working in: a. NPI (New Product Introduction) was exposed to injury while operating the Wysong Shear, Machine Number M-28, Model Number 1251, because the Wysong Shear was not guarded in accordance with the standard. b. NPI (New Product Introduction) was exposed to injury while operating the Di-Acro Houbaille Power Roller, Machine Number M-207, Model Number 24, Serial Number 44507733, because the rotating pinch rollers were not guarded in accordance with the standard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Jun 15, 2018
- Penalty
- Initial $8,130 · Current $8,130
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about February 13, 2018, employees working in the Tool Room at the Alliant Machine Tool, Model Number 1158-5V, Serial Number 1158-5V-1152, were exposed to embolism hazards because the compressed air used for cleaning purposes was measured at 104.9 psi. The relief ports on the air gun nozzle were taped shut. On or about February 13, 2018, employees working in the Tool Room at the Haas Tool Room Mill, Machine Number M1466, Model Number TM-1, Serial Number 48430, were exposed to embolism hazards because the compressed air used for cleaning purposes was measured at 64.4 psi. The relief ports on the air gun nozzle were cut off.
Recent events (2)
- — I (S) $8130
- — Z (S) $8130
1910.303 F01
- Issued
- Jun 15, 2018
- Penalty
- Initial $8,130 · Current $8,130
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about February 13, 2018, employees working in the Tool Room were exposed to injury because the disconnect switch for the 600 Lathes Limited Lathe, Model Number Alpha 400, Serial Number A30167, and the Bergonzi F32 Radial Drill, Machine Number M-467, was not marked to indicate its purpose.
Recent events (2)
- — I (S) $8130
- — Z (S) $8130
1910.303 G01
- Issued
- Jun 15, 2018
- Penalty
- Initial $8,130 · Current $8,130
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about February 13, 2018, employees working in the Tool Room were exposed to injury because the electrical panels were blocked.
Recent events (2)
- — I (S) $8130
- — Z (S) $8130
1910.305 G01 IV A
- Issued
- Jun 15, 2018
- Abate by
- Aug 7, 2018
- Penalty
- Initial $8,130 · Current $8,130
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about May 10, 2018, employees working in the Press Area were exposed to electrical shock hazards because: a. the computer and monitor located behind the Cincinnati Press Brake, Machine Number M833, were plugged into a 6-outlet power strip which was plugged into an extension cord which was plugged into another 6-outlet power strip which was plugged into a wall outlet. b. the two fans located between Cincinnati Press Brake, Machine Number M833, and Cincinnati Press Brake, Machine Number 1179, were each plugged into a 4-outlet electrical adapter which was plugged into an extension cord which was plugged into a 6-outlet power strip which was plugged into a wall outlet. c. the pedestal fan located between Cincinnati Press Brake, Machine Number 1179, and Cincinnati Press Brake, Machine Number 1167, was plugged into an extension cord which was plugged into another extension cord which was plugged into a wall outlet. d. the fluorescent light fixture located above the Amada America, Inc. Press Brake, Machine Number 1164, was plugged into an extension cord which was plugged into a wall outlet.
Recent events (2)
- — I (S) $8130
- — Z (S) $8130
More inspections at Matcor Metal Fabrication, INC.
View Matcor Metal Fabrication, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342951878.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.