KANSAS CITY, KS ·
OSHA Inspection: MAGNA - PLUS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAGNA - PLUS, INC. in 2828 S. 44TH STREET, KANSAS CITY, KS 66106 (NAICS 322226). OSHA activity number 342952173.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNA - PLUS, INC.
- Site address
- 2828 S. 44TH STREET
- City
- KANSAS CITY
- State
- KS
- ZIP
- 66106
- Mailing
- 2828 S. 44TH STREET, KANSAS CITY, KS 66106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322226
- Employees
- 34
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.304 A02
- Issued
- Apr 12, 2018
- Abate by
- May 8, 2018
- Penalty
- Initial $7,760 · Current $5,432 Reduced
General-duty citation text
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity: Employees in the Press Room engaged in daily production activities were exposed to electrical shock and fire hazards in that the extension cord was plugged in to an elevated outlet in such a way as to reverse the polarity of the conductors.
Recent events (2)
- · I (S) $5432
- · Z (S) $7760
1910.304 G05
- Issued
- Apr 12, 2018
- Abate by
- May 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Employees in the Press Room engaged in daily production activities were exposed to electrical shock and fire hazards in that the extension cord was missing its ground conductor pin.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV B
- Issued
- Apr 12, 2018
- Abate by
- May 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: Employees in the Press Room engaged in daily production activities were exposed to electrical shock and fire hazards in that the extension cord was run through a wall and a drop ceiling grid.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Magna - Plus, INC.
View Magna - Plus, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322226)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342952173.