OSHA Inspection: APPLETON GRP, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of APPLETON GRP, LLC in 13639 ALDINE WESTFIELD RD., HOUSTON, TX 77039 (NAICS 335932). OSHA activity number 342953874.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Appleton GRP, LLC — free Get an email when a new federal OSHA severe-injury report for Appleton GRP, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
APPLETON GRP, LLC
Site address
13639 ALDINE WESTFIELD RD.
City
HOUSTON
State
TX
ZIP
77039
Mailing
13639 ALDINE WESTFIELD RD., HOUSTON, TX 77039
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335932
Employees
118
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 8, 2018
Abate by
Mar 27, 2018
Penalty
Initial $9,239 · Current $3,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or about February 15, 2018, and times prior thereto, in the Machine Shop where an employee was exposed to struck-by-hazards when operating a Rockwell 3-spindle drill press without a point of operation guard.
Recent events (3)
  • — F (S) $3000
  • — C (S) $9239
  • — Z (S) $9239

1910.134 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Mar 8, 2018
Abate by
Mar 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  On or about February 14, 2018, and times prior thereto, in the Machine Shop where an employee was provided and allowed to wear a 3M half-face respirator and a N 95 filtering facepiece respirator (dust mask) without being provided with the information contained in Appendix D to 29 CFR 1910.134.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 1 instance 1 exposed
Issued
Mar 8, 2018
Abate by
Mar 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  On or about February 14, 2018, and times prior thereto, in the Machine Shop where an employee was provided and allowed to wear a 3M half-face respirator without the establishment and implementation of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use the respirator and that the respirator was cleaned, stored, and maintained properly.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Appleton GRP, LLC's full OSHA safety record →