SEATTLE, WA —
OSHA Inspection: EAST WEST SEAFOOD'S, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of EAST WEST SEAFOOD'S, LLC in F/V PACIFIC PRODUCER 7001 SEAVIEW AVE. N.W., SEATTLE, WA 98117 (NAICS 336611). OSHA activity number 342956646.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAST WEST SEAFOOD'S, LLC
- Site address
- F/V PACIFIC PRODUCER 7001 SEAVIEW AVE. N.W.
- City
- SEATTLE
- State
- WA
- ZIP
- 98117
- Mailing
- P O BOX 124, KODIAK, AK 99615
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 6
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.106 D04 I
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $7,114 · Current $7,114
General-duty citation text
29 CFR 1910.106(d)(4)(i): Inside storage rooms were not constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, to include openings to the room(s) be provided with approved self-closing fire doors and the room(s) be liquid-tight where the walls join the floor: a) F/V Pacific Producer Main Deck Room 4, where approximately 80-100 gallons of flammable products including, but not limited to, gasoline, International Epoxy Paint Parts A and B, and Sunnyside Lacquer Thinner, were stored in an unventilated room constructed of wood that was not equipped with a self-closing fire door.
Recent events (3)
- — R (S) $7114
- — C (S) $7114
- — Z (S) $7114
1910.106 D04 IV
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(4)(iv): Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system: a) F/V Pacific Producer Main Deck Room 4, where approximately 80-100 gallons of flammable products including, but not limited to, gasoline, International Epoxy Paint Parts A and B, and Sunnyside Lacquer Thinner, were stored in a room that was not equipped with a ventilation system.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.120 Q06 III
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.120(q)(6)(iii): Employees who participated as hazardous materials technicians, or were expected to participate as hazardous materials technicians, had not received at least 24 hours of training equal to the first responder operations level, and in addition have competency in the areas outlined in 29 CFR 1910.120(q)(6)(iii)(A) through (q)(6)(iii)(I) and/or the employer did not so certify: a) F/V Pacific Producer, training had not been provided to employees that were designated to stop leaks in the ammonia refrigeration system.
Recent events (3)
- — R (S) $9959
- — C (S) $9959
- — Z (S) $9959
1910.134 C01
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $9,959 · Current $9,959
0170
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) F/V Pacific Producer, where the employer provided respirators such as, but not limited to, MSA gas masks with ammonia cartridges and self-contained breathing apparatus (SCBA) to employees for use in the event of a refrigeration system ammonia leak.
Recent events (3)
- — R (S) $9959
- — C (S) $9959
- — Z (S) $9959
1910.134 K01 III
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1)(iii): The employer did not ensure that each user could demonstrate knowledge of how to use the respirator effectively in emergency situations, including situations in which the respirator malfunctions: a) F/V Pacific Producer, where the employer provided respirators such as, but not limited to, MSA gas masks with ammonia cartridges and self-contained breathing apparatus (SCBA) to employees for use in the event of emergencies such as, a refrigeration system ammonia leak.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 H03 I B
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(3)(i)(B): Respirators maintained for use in emergency situations were not inspected at least monthly and in accordance with manufacturer recommendations: a) F/V Pacific Producer Main Deck, where the employer provided MSA gas masks with ammonia cartridges were provided for escape in the event of a refrigeration system ammonia leak.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 H03 III
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(3)(iii): Self-contained breathing apparatus was not inspected monthly: a) F/V Pacific Producer Main Deck, monthly inspections were not performed where two self-contained breathing apparatus (SCBA) were provided for use in the event of a refrigeration system ammonia leak.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 H03 IV A
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.134(h)(3)(iv)(A): The employer did not certify the respirator by documenting the date the inspection was performed, the name (or signature) of the person who made the inspection, the findings, required remedial action, and a serial number or other means of identifying the inspected respirator: a) F/V Pacific Producer Main Deck, respirator inspections were not certified, where two self-contained breathing apparatus (SCBA) were provided for use in the event of a refrigeration system ammonia leak.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 H03 IV B
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.134(h)(3)(iv)(B): Certification information on a tag or label was not attached to the storage compartment for the respirator and kept with the respirator or included in inspection reports stored as paper or electronic files: a) F/V Pacific Producer Main Deck, respirator inspections were not documented, where two self-contained breathing apparatus (SCBA) were provided for use in the event of a refrigeration system ammonia leak.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $5,691 · Current $5,691
0170
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): a) F/V Pacific Producer, where safety data sheets were not maintained for chemicals including, but not limited to, anhydrous ammonia, International Paints Part A and Part B, Sunnyside lacquer thinner, Gloss spray paint, and gasoline.
Recent events (3)
- — R (S) $5691
- — C (S) $5691
- — Z (S) $5691
1910.1200 H03 III
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: a) F/V Pacific Producer, where employees had not received training in the measures to protect themselves from hazards associated with chemicals in the work place including, but not limited to, anhydrous ammonia, International Paints Part A and Part B, Sunnyside lacquer thinner, Gloss spray paint, and gasoline.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
5(a)(1)
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $9,959 · Current $9,959
0170
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) F/V Pacific Producer, where employees were potentially exposed to inhalation hazards from an uncontrolled release of anhydrous ammonia from the charged refrigeration system that contained 6500 pounds of anhydrous ammonia. A maintenance and repair program for the ammonia refrigeration system did not include: 1. Where the employer did not maintain a written system component inventory list. 2. Where the employer did not develop a written systems maintenance and inspection log to ensure the safety of the refrigerating systems. 3. Where corrosion protection was not uniform on all uninsulated piping and associated components such as flanges, the employer did not perform inspections to evaluate corrosion damage. 4. Where the employer did not post the location of protective, first aid and rescue equipment on notices within and external to the work areas containing anhydrous ammonia.
Recent events (3)
- — R (S) $9959
- — C (S) $9959
- — Z (S) $9959
1910.1200 E01
- Issued
- Apr 24, 2018
- Abate by
- Jun 6, 2018
- Penalty
- Initial $14,228 · Current $14,228
0170
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) F/V Pacific Producer, where the employer did not develop a written hazard communication program. Employees utilized chemicals such as, but not limited to, International Paints Part A and Part B, Sunnyside lacquer thinner, Gloss spray paint, and gasoline. The charged refrigeration system located on board contained 6500 pounds of anhydrous ammonia. The East West Seafoods, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(e)(1), which was contained in OSHA inspection number 956718, citation number 1, item number 2, and was affirmed as a final order on March 6, 2014, with respect to a workplace located at ISA Dock, Kodiak, AK.
Recent events (3)
- — R (R) $14228
- — C (R) $14228
- — Z (R) $14228
More inspections at East West Seafood'S, LLC
View East West Seafood'S, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342956646.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.