Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CATES CASTSTONE COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CATES CASTSTONE COMPANY, INC. in 12783 FM 346 EAST, WHITEHOUSE, TX 75791 (NAICS 327390). OSHA activity number 342967338.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cates Caststone Company, INC. — free Get an email when a new federal OSHA severe-injury report for Cates Caststone Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12783 FM 346 EAST
City
WHITEHOUSE
State
TX
ZIP
75791
Mailing
P.O.BOX 576, WHITEHOUSE, TX 75791
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
15
Ownership type
A

11 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $3,696 · Current $1,100 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) On or about February 22, 2018 a Delta drill press was found with its chuck and bit not guarded exposing employees who used it to a caught-in hazard.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $3696

1910.212 B

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $2,956 · Current $900 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    (a) On or about February 22, 2018 a Delta band saw was found not anchored to the floor exposing employees who used it to a tip-over hazard.
Recent events (2)
  • — I (S) $900
  • — Z (S) $2956

1910.213 A09

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $5,174 · Current $1,585 Reduced
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219:    (a) On or about February 22, 2018 a Delta band saw was found with its belt and pulley only partially guarded by a fabricated sheet metal cover which enclosed the top, side, and ends. Employee operating the band saw were exposed to a caught-in hazard from the rotating nip points.
Recent events (2)
  • — I (S) $1585
  • — Z (S) $5174

1910.213 I01

Serious Gravity 10 2 instances 3 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of a band saw were not enclosed or guarded:  (a) On or about February 22, 2018 a Delta band saw was found in the mold shop with approximately 5 inches of the top portion of its blade unguarded exposing employees using it to an amputation hazard.  (b) On or about February 22, 2018 a Delta band saw was found in the mold shop with approximately 3 and 1/4 inches of the bottom portion of its blade unguarded exposing employees using it to an amputation hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $2,217 · Current $675 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      (a) This violation occurred in the mold shop where employees were using unregulated compressed air (approximately 120 p.s.i) to blow dust and debris off of the machines and the floor, exposing them to a struck-by hazard.
Recent events (2)
  • — I (S) $675
  • — Z (S) $2217

1910.303 G01 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $3,696 · Current $1,100 Reduced
29 CFR 1910.303(g)(1)(vii): Switchboards, panel boards, and distribution boards installed for the control of light and power circuits, and motor control centers were not located in dedicated spaces and protected from damage:    (a) On or about February 22, 2018 a 480 Volt electrical panel board located in the mold shop was found damaged in that a piece of the panel had broken lose and fallen inside of the panel exposing live electrical parts. Employees accessing the panel were exposed to an electrical shock hazard.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $3696

1910.305 B01 I

Serious Gravity 5 1 instance 11 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $3,696 · Current $1,100 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions and the openings through which they entered were not effectively closed:    (a) On or about February 22, 2018 in the mixing area, an outlet box that the mixer was plugged into was found with its electrical conductors not fully encased in the conduit and and not protected from abrasions exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $3696

1910.305 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) On or about February 22, 2018, in the mixer area, an outlet box that the mixer was plugged into was found without a faceplate exposing employees using it to an electrical shock hazard of approximately 460 Volts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 19, 2018
Abate by
May 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) On or about February 22, 2018 an flexible cord that was plugged into an outlet box and powering a mixer was found with no strain relief at its connector exposing employees using it to an electrical shock hazard of approximately 460 Volts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 3 instances 11 exposed
Issued
Apr 19, 2018
Abate by
Jul 19, 2018
Penalty
Initial $3,696 · Current $1,100 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a) On or about February 22, 2018 a flexible cord was found in the mixing area powering a work light which was temporarily attached to a steel pillar of the building. The cord was being used in lieu of permanent wiring exposing employees in the area to an inhalation hazard in the event of an electrical fire.    (b) On or about February 22, 2018 a flexible cord with a power strip end attached to it was found in the mixing area powering a fan which was hanging from the buildings structural members by chains. The cord was being used in lieu of permanent wiring exposing employees in the area to an inhalation hazard in the event of an electrical fire.    (c) On or about February 22, 2018 a flexible cord was found in the mold shop powering a fluorescent light fixture which was attached to a non-operating permanently mounted fluorescent light fixture by the use of electrical wiring causing it to hang below it. The cord was being used in lieu of permanent wiring exposing employees in the area to an inhalation hazard in the event of an electrical fire.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $3696

1910.305 G01 IV D

Serious Gravity 5 3 instances 11 exposed
Issued
Apr 19, 2018
Abate by
Jul 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces:  (a) On or about February 22, 2018 a flexible cord was found in the mixing area powering a work light which was temporarily attached to a steel pillar of the building. The cord was attached to building surfaces by tying it and using plastic zip ties exposing employees in the area to an inhalation hazard in the event of an electrical fire.  (b) On or about February 22, 2018 a flexible cord with a power strip end attached to it was found in the mixing area powering a fan which was hanging from the buildings structural members by chains. The cord was attached to a beam and pipe with plastic zip ties and tape exposing employees in the area to an inhalation hazard in the event of an electrical fire.  (c) On or about February 22, 2018 a flexible cord was found in the mold shop powering a fluorescent light fixture which was attached to a non-operating, permanently mounted fluorescent light fixture by the use of electrical wiring causing it to hang below it. The cord was tied back to the wall of the structure with a plastic zip tie exposing employees in the area to an inhalation hazard in the event of an electrical fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Cates Caststone Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342967338.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.