WHITEHOUSE, TX —
OSHA Inspection: CATES CASTSTONE COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CATES CASTSTONE COMPANY, INC. in 12783 FM 346 EAST, WHITEHOUSE, TX 75791 (NAICS 327390). OSHA activity number 342967338.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CATES CASTSTONE COMPANY, INC.
- Site address
- 12783 FM 346 EAST
- City
- WHITEHOUSE
- State
- TX
- ZIP
- 75791
- Mailing
- P.O.BOX 576, WHITEHOUSE, TX 75791
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 15
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.212 A03 II
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $3,696 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) On or about February 22, 2018 a Delta drill press was found with its chuck and bit not guarded exposing employees who used it to a caught-in hazard.
Recent events (2)
- — I (S) $1100
- — Z (S) $3696
1910.212 B
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $2,956 · Current $900 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) On or about February 22, 2018 a Delta band saw was found not anchored to the floor exposing employees who used it to a tip-over hazard.
Recent events (2)
- — I (S) $900
- — Z (S) $2956
1910.213 A09
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $5,174 · Current $1,585 Reduced
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219: (a) On or about February 22, 2018 a Delta band saw was found with its belt and pulley only partially guarded by a fabricated sheet metal cover which enclosed the top, side, and ends. Employee operating the band saw were exposed to a caught-in hazard from the rotating nip points.
Recent events (2)
- — I (S) $1585
- — Z (S) $5174
1910.213 I01
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of a band saw were not enclosed or guarded: (a) On or about February 22, 2018 a Delta band saw was found in the mold shop with approximately 5 inches of the top portion of its blade unguarded exposing employees using it to an amputation hazard. (b) On or about February 22, 2018 a Delta band saw was found in the mold shop with approximately 3 and 1/4 inches of the bottom portion of its blade unguarded exposing employees using it to an amputation hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $2,217 · Current $675 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) This violation occurred in the mold shop where employees were using unregulated compressed air (approximately 120 p.s.i) to blow dust and debris off of the machines and the floor, exposing them to a struck-by hazard.
Recent events (2)
- — I (S) $675
- — Z (S) $2217
1910.303 G01 VII
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $3,696 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(vii): Switchboards, panel boards, and distribution boards installed for the control of light and power circuits, and motor control centers were not located in dedicated spaces and protected from damage: (a) On or about February 22, 2018 a 480 Volt electrical panel board located in the mold shop was found damaged in that a piece of the panel had broken lose and fallen inside of the panel exposing live electrical parts. Employees accessing the panel were exposed to an electrical shock hazard.
Recent events (2)
- — I (S) $1100
- — Z (S) $3696
1910.305 B01 I
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $3,696 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions and the openings through which they entered were not effectively closed: (a) On or about February 22, 2018 in the mixing area, an outlet box that the mixer was plugged into was found with its electrical conductors not fully encased in the conduit and and not protected from abrasions exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $1100
- — Z (S) $3696
1910.305 B02 I
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or about February 22, 2018, in the mixer area, an outlet box that the mixer was plugged into was found without a faceplate exposing employees using it to an electrical shock hazard of approximately 460 Volts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Apr 19, 2018
- Abate by
- May 15, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) On or about February 22, 2018 an flexible cord that was plugged into an outlet box and powering a mixer was found with no strain relief at its connector exposing employees using it to an electrical shock hazard of approximately 460 Volts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Apr 19, 2018
- Abate by
- Jul 19, 2018
- Penalty
- Initial $3,696 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about February 22, 2018 a flexible cord was found in the mixing area powering a work light which was temporarily attached to a steel pillar of the building. The cord was being used in lieu of permanent wiring exposing employees in the area to an inhalation hazard in the event of an electrical fire. (b) On or about February 22, 2018 a flexible cord with a power strip end attached to it was found in the mixing area powering a fan which was hanging from the buildings structural members by chains. The cord was being used in lieu of permanent wiring exposing employees in the area to an inhalation hazard in the event of an electrical fire. (c) On or about February 22, 2018 a flexible cord was found in the mold shop powering a fluorescent light fixture which was attached to a non-operating permanently mounted fluorescent light fixture by the use of electrical wiring causing it to hang below it. The cord was being used in lieu of permanent wiring exposing employees in the area to an inhalation hazard in the event of an electrical fire.
Recent events (2)
- — I (S) $1100
- — Z (S) $3696
1910.305 G01 IV D
- Issued
- Apr 19, 2018
- Abate by
- Jul 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: (a) On or about February 22, 2018 a flexible cord was found in the mixing area powering a work light which was temporarily attached to a steel pillar of the building. The cord was attached to building surfaces by tying it and using plastic zip ties exposing employees in the area to an inhalation hazard in the event of an electrical fire. (b) On or about February 22, 2018 a flexible cord with a power strip end attached to it was found in the mixing area powering a fan which was hanging from the buildings structural members by chains. The cord was attached to a beam and pipe with plastic zip ties and tape exposing employees in the area to an inhalation hazard in the event of an electrical fire. (c) On or about February 22, 2018 a flexible cord was found in the mold shop powering a fluorescent light fixture which was attached to a non-operating, permanently mounted fluorescent light fixture by the use of electrical wiring causing it to hang below it. The cord was tied back to the wall of the structure with a plastic zip tie exposing employees in the area to an inhalation hazard in the event of an electrical fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Cates Caststone Company, INC.
View Cates Caststone Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342967338.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.