RUSSELLVILLE, AR —
OSHA Inspection: HACKNEY LADISH, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HACKNEY LADISH, INC. in 708 S. ELMIRA AVE., RUSSELLVILLE, AR 72802 (NAICS 332996). OSHA activity number 342968245.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HACKNEY LADISH, INC.
- Site address
- 708 S. ELMIRA AVE.
- City
- RUSSELLVILLE
- State
- AR
- ZIP
- 72802
- Mailing
- 708 S. ELMIRA AVE., RUSSELLVILLE, AR 72802
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 190
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A02
- Issued
- Jun 20, 2018
- Abate by
- Jul 19, 2018
- Penalty
- Initial $10,975 · Current $6,585 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition. On or about February 22, 2018, and at times prior thereto, at Hackney Ladish located in Russellville, Arkansas, where the employer did not ensure SafeTSorb oil absorbent was adequately cleaned daily from the walking/working surfaces.
Recent events (2)
- — I (O) $6585
- — Z (S) $10975
1910.157 C01
- Issued
- Jun 20, 2018
- Abate by
- Jul 19, 2018
- Penalty
- Initial $5,488 · Current $3,293 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about April 22, 2018, and at times prior thereto, on the Production floor at the Heat Treat, where the employer did not ensure that the portable fire extinguisher was mounted in a location that was readily accessible and available without subjecting the employees to bodily injuries in case of fire.
Recent events (2)
- — I (O) $3292.8
- — Z (S) $5488
1910.212 A01
- Issued
- Jun 20, 2018
- Penalty
- Initial $12,805 · Current $7,683 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about February 19, 2018, and times prior thereto, in the production department, where the employer did not ensure unused portion of the Hyd-Mech Machine #566 horizontal bandsaw blade was equipped with adequate guarding.
Recent events (2)
- — I (S) $7683
- — Z (S) $12805
1910.303 B02
- Issued
- Jun 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about February 22, 2018, and times prior thereto, on the production department at Bevel machine 1091, where the employer used duct tape to hold rigid conduit that houses the electrical cord to the equipment light housing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02 IX
- Issued
- Jun 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard On or about February 22, 2018, and times prior thereto, on the production floor at Bevel machine 1091, where the employer did not ensure the lighting at operator workstation was guarded from accidental contact or breakage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.334 A02 I
- Issued
- Jun 20, 2018
- Abate by
- Jul 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): On or about February 22, 2018, and times prior thereto, on the production floor at 509 torch, employees operated a torch in which its cord outer jacket was torn, exposing the cord insulation underneath.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Hackney Ladish, INC.
View Hackney Ladish, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342968245.