On , OSHA opened a complaint safety inspection of J.A.C.K. WOOD PRODUCTS, LLC in 150 ROSE STREET, GLEN HOPE, PA 16645 (NAICS 321113). OSHA activity number 342972643.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.A.C.K. WOOD PRODUCTS, LLC
- Site address
- 150 ROSE STREET
- City
- GLEN HOPE
- State
- PA
- ZIP
- 16645
- Mailing
- 150 ROSE STREET, GLEN HOPE, PA 16645
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 3
- Ownership type
- A
Citations
16 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 21, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $2,217 · Current $1,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: Employees were potentially exposed to fire, burn, and deflagration hazards from a DISA dust collector that was not equipped with devices and systems to prevent the propagation of deflagration and associated flame fronts from the dust collector through the associated dust collection system duct work and back into the building. The DISA dust collector was not equipped with approved devices to prevent the propagation of deflagration and associated flame fronts throughout the dust collection system. The dust collector collected wood dust.
Recent events (2)
- — I (S) $1000
- — Z (S) $2217
1910.22 A01
- Issued
- Aug 21, 2018
- Abate by
- Oct 9, 2018
- Penalty
- Initial $2,217 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, sawmill, on or about March 22, 2018 and times prior thereto: Employees generated saw dust that accumulated on surfaces including, but not limited to, electrical disconnect boxes, lighting fixtures, sawmill machinery, and an overhead garage door. Dust accumulations were between a 1/32 and 1-1/2 inches. B.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, woodworking area, on or about March 22, 2018 and times prior thereto: Employees generated saw dust that accumulated on surfaces including, but not limited to, duct work for the dust collection system. Dust accumulations were at least 1/16 inch.
Recent events (2)
- — I (S) $1300
- — Z (S) $2217
1910.22 A02
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The floor of each workroom were not maintained in a clean and, to the extent feasible, in a dry condition: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, sawmill, on or about March 22, 2018 and times prior thereto: Employees generated saw dust that accumulated on floor surfaces. Dust accumulations were at least 1/8 of an inch on the floor areas.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $2,217 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: An authorized employee was designated to perform service and maintenance on equipment including, but not limited to, rip saw #4. The authorized employee was not affixing an energy isolation device to the electrical power source that isolated the mechanical energy of the machine.
Recent events (2)
- — I (S) $1000
- — Z (S) $2217
1910.147 C06 I
- Issued
- Aug 21, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: An authorized employee was designated to perform service and maintenance on equipment including, but not limited to, rip saw #4. The employer had not conducted periodic inspections of the energy control procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.265 E05 II A
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $2,217 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.265(e)(5)(ii)(a): The top(s) and opening(s) in end and side frame(s) of edger(s) were not adequately guarded: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, storage area, on or about February 23, 2018 and times prior thereto: Employees operate a Cooks edger for sawmill operations. There was a 3-inch wide opening in the side of the edger which allowed access into the saw blade area.
Recent events (2)
- — I (S) $1000
- — Z (S) $2217
1910.219 D01
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: The power transmission belt and pulley system used to power the rollers on the Cooks edger was not adequately guarded. The belt and pulley system was with five-feet of the floor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $1,663 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, kitchenette area, on or about March 22, 2018 and times prior thereto: An electrical junction box containing an energized wire was not equipped with a cover plate.
Recent events (2)
- — I (S) $1000
- — Z (S) $1663
1910.303 G01 II
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, storage area, on or about February 23, 2018 and times prior thereto: Items including, but not limited to, a trash can and a wooden dresser were stored in front of an electrical breaker box and electrical disconnects.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B05
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, storage area, on or about March 22, 2018 and times prior thereto: A door in the storage building that was blocked by a sheet of plywood and was not marked "Not an Exit".
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 D02
- Issued
- Aug 21, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: Employees are provided with and are required to wear PPE including, but not limited to, safety glasses. The company did not certify their PPE hazard assessment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.145 C03
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, boiler room area, on or about February 23, 2018 and times prior thereto: The boiler did not contain a sign to inform employees of the thermal hazards associated with the boiler.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, storage area, on or about February 23, 2018 and times prior thereto: An Amerex portable multi-purpose dry chemical fire extinguisher was exposed to damage in that it was on the floor and not mounted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: Employees are provided with, and permitted to use, portable dry chemical fire extinguishers. The employees did not inspect the fire extinguishers monthly.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G02
- Issued
- Aug 21, 2018
- Abate by
- Sep 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: Employees are provided with, and permitted to use, portable dry chemical fire extinguishers. The employees did not have initial fire extinguisher training. B.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, on or about February 23, 2018 and times prior thereto: Employees are provided with, and permitted to use, portable dry chemical fire extinguishers. The employees did not have annual fire extinguisher training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.265 C06 II
- Issued
- Aug 21, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(c)(6)(ii): Exits were not located and identified in a manner that afforded ready exit from work area(s): A.) J.A.C.K. Wood Products, LLC, 150 Rose Street, Glen Hope, PA 16645, storage area, on or about March 22, 2018 and times prior thereto: Exits in the storage building were not equipped with exit signage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at J.A.C.K. Wood Products, LLC
View J.A.C.K. Wood Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342972643.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.