Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CKJK, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CKJK, LLC in 150 ROSE STREET, GLEN HOPE, PA 16645 (NAICS 321999). OSHA activity number 342972759.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ckjk, LLC — free Get an email when a new federal OSHA severe-injury report for Ckjk, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CKJK, LLC
Site address
150 ROSE STREET
City
GLEN HOPE
State
PA
ZIP
16645
Mailing
150 ROSE STREET, GLEN HOPE, PA 16645
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
5
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 21, 2018
Abate by
Jan 4, 2019
Penalty
Initial $2,217 · Current $1,000 Reduced

Hazardous substances E200

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  Employees were potentially exposed to fire, burn, and deflagration hazards from a DISA dust collector that was not equipped with devices and systems to prevent the propagation of deflagration and associated flame fronts from the dust collector through the associated dust collection system duct work and back into the building. The DISA dust collector was not equipped with approved devices to prevent the propagation of deflagration and associated flame fronts throughout the dust collection system. The dust collector collected wood dust.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2217

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2018
Abate by
Sep 17, 2018
Penalty
Initial $2,217 · Current $1,050 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  An authorized employee was designated to perform service and maintenance on equipment including, but not limited to, the pellet mill.  The authorized employee was not affixing an energy isolation device to the electrical power source that isolated the mechanical energy of the machine.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2217

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2018
Abate by
Sep 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  An employee was designated to perform service and maintenance on equipment including, but not limited to, the pellet mill.  The employee was not trained as an authorized employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2018
Abate by
Sep 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:  A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  An authorized employee was designated to perform service and maintenance on equipment including, but not limited to, the pellet mill.  The employer had not conducted periodic inspections of the energy control procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 21, 2018
Abate by
Sep 17, 2018
Penalty
Initial $1,663 · Current $1,000 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, pellet manufacturing area, on or about March 22, 2018 and times prior thereto:  A flexible electrical extension cord was running from an electrical receptacle to a second flexible cord.  The flexible cords were powering equipment including, but not limited to, a phone light.  The flexible cords were being used as fixed wiring of a structure.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1663

1910.305 B02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 21, 2018
Abate by
Sep 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, kitchenette area, on or about March 22, 2018 and times prior thereto:  An electrical junction box containing an energized wire was not equipped with a cover plate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D02

Other-than-serious 1 instance 5 exposed
Issued
Aug 21, 2018
Abate by
Sep 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:   A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  Employees are provided with and are required to wear PPE including, but not limited to, safety glasses.  The company did not certify their PPE hazard assessment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 5 exposed
Issued
Aug 21, 2018
Abate by
Oct 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  Employees are provided with, and permitted to use, portable dry chemical fire extinguishers.  The employees did not inspect the fire extinguishers monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 G02

Other-than-serious 2 instances 5 exposed
Issued
Aug 21, 2018
Abate by
Sep 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  A.) CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  Employees are provided with, and permitted to use, portable dry chemical fire extinguishers.  The employees did not have initial fire extinguisher training.   B.) CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  Employees are provided with, and permitted to use, portable dry chemical fire extinguishers.  The employees did not have annual fire extinguisher training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 A03

Other-than-serious 1 instance 5 exposed
Issued
Aug 21, 2018
Abate by
Sep 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  A.)  CKJK, LLC dba Pellheat, 150 Rose Street, Glen Hope, PA  16645, on or about February 23, 2018 and times prior thereto:  The exit door leading from the Pellheat pellet manufacturing area to the woodworking building was blocked by items including, but not limited to, a drum and items stacked on a wooden pallet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Ckjk, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342972759.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.