Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE ELECTRODYNE COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE ELECTRODYNE COMPANY in 4188 TAYLOR ROAD, BATAVIA, OH 45103 (NAICS 327110). OSHA activity number 342983194.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Electrodyne Company — free Get an email when a new federal OSHA severe-injury report for The Electrodyne Company is published. One employer, no account, unsubscribe in one click.
Site address
4188 TAYLOR ROAD
City
BATAVIA
State
OH
ZIP
45103
Mailing
4188 TAYLOR ROAD, BATAVIA, OH 45103
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327110
Employees
14
Ownership type
A

5 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 13, 2018
Abate by
Jun 18, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    On February 22, 2018, in the Production Area, a mill operator was exposed to a pinch point hazard from the lack of point of operation guarding on the Farrel  SN 44217, 14 inch mill machine.
Recent events (2)
  • — I (S) $5174
  • — Z (S) $5174

1910.216 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 13, 2018
Abate by
Jun 18, 2018
Penalty
Initial $3,696 · Current $0 Reduced
29 CFR 1910.216(b)(1)(ii): Safety triprod. Installed in the front and in the back of each mill and located within 2 inches of a vertical plane tangent to the front and rear rolls. The top rods shall be not more than 72 inches above the level on which the operator stands. The triprods shall be accessible and shall operate readily whether the rods are pushed or pulled.    On the Farrel, SN 44217, 14 inch mill machine the two push-pull hand brakes (round metal rod) located on each end of the face or the front and rear of the 14 inch mill roller was not located within 2 inches of a vertical plane tangent to the front and rear rolls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3696

1910.1030 G02 I

Serious Gravity 5 1 instance 14 exposed
Issued
Apr 13, 2018
Abate by
Jun 18, 2018
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.151(d): The employer failed to demonstrate that it had trained two employees adequately on the hazard of exposure to blood prior to the work-related injury on February 22, 2018."    The employer had not trained two employees with occupational exposure prior to the work-related injury on February 22, 2018 when they cleaned up blood on a 14 inch roller of a Farrel Mill Machine and on the floor.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1904.39 A02

Other-than-serious 1 instance 14 exposed
Issued
Apr 13, 2018
Abate by
Jun 18, 2018
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1904.39(a)(2): Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.    The employer did not report an in-patient hospitalization of a work-related injury that occurred on February 22, 2018 until February 27, 2018.
Recent events (2)
  • — I (O) $1848
  • — Z (O) $3696

1910.1030 C01 I

Deleted Other-than-serious 1 instance 14 exposed
Issued
Apr 13, 2018
Abate by
May 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(i): Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.  The employer did not have a written exposure control plan to eliminate or minimize employee exposure to bloodborne pathogens.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Electrodyne Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342983194.