ERIE, PA —
OSHA Inspection: TM INDUSTRIAL SUPPLY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TM INDUSTRIAL SUPPLY, INC. in 1432 WALNUT STREET, ERIE, PA 16502 (NAICS 333132). OSHA activity number 342983509.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TM INDUSTRIAL SUPPLY, INC.
- Site address
- 1432 WALNUT STREET
- City
- ERIE
- State
- PA
- ZIP
- 16502
- Mailing
- 1432 WALNUT STREET, ERIE, PA 16502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333132
- Employees
- 32
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 6, 2018
- Abate by
- May 2, 2018
- Penalty
- Initial $6,467 · Current $4,527 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A.) TM Industrial Supply, Inc., 1432 Walnut Street, Erie, PA 16502, saw area, on or about February 28, 2018 and times prior thereto: Employees utilize a DoAll C-916 horizontal band saw to cut materials including, but not limited to, steel pipe. The unused portion of the band saw blade was not guarded. B.) TM Industrial Supply, Inc., 1432 Walnut Street, Erie, PA 16502, sheet metal fabrication area, on or about February 28, 2018 and times prior thereto: Employee use a Birmingham H-6010 shear to preform work operations including, but not limited to, cutting sheet metal. The hold downs on the Birmingham H-6010 shear were not guarded. C.) TM Industrial Supply, Inc., 1432 Walnut Street, Erie, PA 16502, machine shop, on or about February 28, 2018 and times prior thereto: Employees utilize a Nardini ND 1585E lathe to perform work operations that include, but are not limited to, chuck turn shafts. The lathe was not equipped with a chuck guard.
Recent events (2)
- — I (S) $4526.9
- — Z (S) $6467
1910.212 A03 II
- Issued
- Apr 6, 2018
- Abate by
- May 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A.) TM Industrial Supply, Inc., 1432 Walnut Street, Erie, PA 16502, sheet metal fabrication area, on or about February 28, 2018 and times prior thereto: Employee use a Birmingham H-6010 shear to preform work operations including, but not limited to, cutting sheet metal. The guarding on the Birmingham H-6010 shear was not effective in that the present guard opening was too large allowing access to the shearing point of operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Apr 6, 2018
- Abate by
- May 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A.) TM Industrial Supply, Inc., 1432 Walnut Street, Erie, PA 16502, on or about February 28, 2018 and times prior thereto: Employees perform service and maintenance on equipment including, but not limited to, blade change outs on the DoAll C-916 horizontal band saw. The employer does not conduct a periodic inspection of the energy control procedure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Apr 6, 2018
- Abate by
- May 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A.) TM Industrial Supply, Inc., 1432 Walnut Street, Erie, PA 16502, weld area, on or about February 28, 2018 and times prior thereto: Items including, but not limited to, a Lincoln Electric 375 Precision TIG welder was stored in front of two electrical disconnects.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at TM Industrial Supply, INC.
View TM Industrial Supply, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333132)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342983509.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.