FRANKLINVILLE, NY —
OSHA Inspection: CATTARAUGUS CONTAINER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CATTARAUGUS CONTAINER, INC. in 21-23 ELM ST, FRANKLINVILLE, NY 14737 (NAICS 322211). OSHA activity number 342999026.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CATTARAUGUS CONTAINER, INC.
- Site address
- 21-23 ELM ST
- City
- FRANKLINVILLE
- State
- NY
- ZIP
- 14737
- Mailing
- P.O. BOX 174, FRANKLINVILLE, NY 14737
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 31
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 19, 2018
- Abate by
- Apr 10, 2018
- Penalty
- Initial $6,467 · Current $3,950 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 03/07/2018 in the production area; where employees perform servicing and/or maintenance such as, but not limited to: cleaning under and around machinery, and setting up machines, without utilizing energy control procedures to lock the machinery in the "off"/deenergized condition. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3950
- — Z (S) $6467
1910.147 C04 II C
- Issued
- Mar 19, 2018
- Abate by
- Apr 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: a) On or about 03/07/2018 in production area; where the employer's energy control procedures did not include procedures for removal of lockout devices by someone other than the employee who applied the device [at a minimum, as outlined in 1910.147(e)(3)(i) through 1910.147(e)(3)(iii)]. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I C
- Issued
- Mar 19, 2018
- Abate by
- Apr 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 03/07/2018 in the production area; where employees perform servicing and maintenance on machines and equipment such as, but not limited to: printing presses, die cutting machines and a partition slotter. The employer did not perform a periodic inspection, at least annually, of employees performing servicing and/or maintenance. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 I
- Issued
- Mar 19, 2018
- Abate by
- Apr 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) On or about 03/07/2018; in the production area; where the power supply conductors for the gluer had come loose from the cord grip and were exposed to abrasion from the fitting on the electrical box. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Mar 19, 2018
- Abate by
- Apr 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about 03/07/2018 in the production area; where there was a missing knockout on top of the disconnect switch mounted on the side of the partition slotter. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Mar 19, 2018
- Abate by
- Apr 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) On or about 03/07/2018 in the production area; where an electrical junction box on the partition slotter was not covered. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cattaraugus Container, INC.
View Cattaraugus Container, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342999026.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.