WILLISTON, ND —
OSHA Inspection: SUN WELL SERVICE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUN WELL SERVICE, INC. in WELL SITE: JUNEAU 11-2H1, WILLISTON, ND 58801 (NAICS 213112). OSHA activity number 343007787.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUN WELL SERVICE, INC.
- Site address
- WELL SITE: JUNEAU 11-2H1
- City
- WILLISTON
- State
- ND
- ZIP
- 58801
- Mailing
- 118 84TH STREET WEST, WILLISTON, ND 58801
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 200
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 9, 2018
- Abate by
- Sep 5, 2018
- Penalty
- Initial $11,641 · Current $6,000 Reduced
General-duty citation text
Section (5)(a)(1): The employer failed to furnish to each of his employees employment and a place of employment which was free from recognized hazards that were causing or are likely to cause death or serious physical harm, in that employees were exposed to struck-by hazards: (a) On or about February 11, 2018 for an employee who was injured after being struck by a 2 3/8 inch diameter tubular that fell out of a Keystone slip-type elevator that was configured to handle a 2 7/8 inch tubular at the Juneau 11-2H1 well site near Williston, North Dakota. Abatement note: Among other feasible and useful means of abatement, the employer can develop policies and procedures designed to ensure the selection and use of appropriately configured elevators. For guidance, the employer can reference the procedures described in the operators manual for Keystone Y-Series elevators, the recommendations found in API RP 54, and the inspection criteria found in API Spec 8c.
Recent events (2)
- — I (S) $6000
- — Z (S) $11641
More inspections at SUN Well Service, INC.
View SUN Well Service, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343007787.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.