Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAPP STEEL ERECTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CAPP STEEL ERECTORS, INC. in 11731 MT. OVERLOOK, CLEVELAND, OH 44120 (NAICS 238120). OSHA activity number 343012456.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capp Steel Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Capp Steel Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11731 MT. OVERLOOK
City
CLEVELAND
State
OH
ZIP
44120
Mailing
6004 STATE RD., ASHTABULA, OH 44004
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 13, 2018
Abate by
Aug 7, 2018
Penalty
Initial $3,696 · Current $2,218 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person:     On or about March 16, 2018, during the installation of structural steel and cross bracing at a new addition to a school located at 11731 Mt. Overlook, Cleveland, Ohio 44120, the employer did not conduct frequent and regular inspections of the job site where employees were exposed to fall hazards from working surfaces of varying heights approximately 14 to 21.8 feet.
Recent events (2)
  • — I (S) $2217.6
  • — Z (S) $3696

1926.760 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 13, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.     On or about March 16, 2018, during the installation of cross bracing on structural steel at the job site located at 11731 Mt. Overlook, Cleveland, Ohio 44120; the employer did not ensure working employees were protected from a fall hazard of 21.8 feet by utilizing a fall protection system.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

View Capp Steel Erectors, INC.'s full OSHA safety record →